A methodology has been developed to perform electrical characterization of the stripline BPMs for the future Gamma Beam System of ELI Nuclear Physics facility in Romania. Several prototype units are extensively benchmarked and the results are presented in this paper. The BPM sensitivity function is determined using a uniquely designed motorized test bench with a stretched wire to measure the BPM response map. Here, the BPM feedthroughs are connected to Libera Brilliance electronics and the wire is fed by continuous wave signal, while the two software-controlled motors provide horizontal and vertical motion of the BPM around the wire. The electrical offset is obtained using S-parameter measurements with a Network Analyzer (via the “Lambertson” method) and is referenced to the mechanical offset

Measurements and calibration of the stripline BPM for the ELI-NP facility with the stretched wire method / Nosych, A. A.; Iriso, U.; Olmos, A.; Crisol, A.; Colldelram, C.; Cioeta, Fara; Falone, A.; Ghigo, A.; Serio, M.; Stella, A.; Mostacci, Andrea. - ELETTRONICO. - (2015), pp. 423-427. (Intervento presentato al convegno IBIC 2015 tenutosi a Melbourne, Australia).

Measurements and calibration of the stripline BPM for the ELI-NP facility with the stretched wire method

CIOETA, Fara;MOSTACCI, Andrea
2015

Abstract

A methodology has been developed to perform electrical characterization of the stripline BPMs for the future Gamma Beam System of ELI Nuclear Physics facility in Romania. Several prototype units are extensively benchmarked and the results are presented in this paper. The BPM sensitivity function is determined using a uniquely designed motorized test bench with a stretched wire to measure the BPM response map. Here, the BPM feedthroughs are connected to Libera Brilliance electronics and the wire is fed by continuous wave signal, while the two software-controlled motors provide horizontal and vertical motion of the BPM around the wire. The electrical offset is obtained using S-parameter measurements with a Network Analyzer (via the “Lambertson” method) and is referenced to the mechanical offset
2015
IBIC 2015
BPM; ELI
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Measurements and calibration of the stripline BPM for the ELI-NP facility with the stretched wire method / Nosych, A. A.; Iriso, U.; Olmos, A.; Crisol, A.; Colldelram, C.; Cioeta, Fara; Falone, A.; Ghigo, A.; Serio, M.; Stella, A.; Mostacci, Andrea. - ELETTRONICO. - (2015), pp. 423-427. (Intervento presentato al convegno IBIC 2015 tenutosi a Melbourne, Australia).
File allegati a questo prodotto
File Dimensione Formato  
Nosych_measurements_2015.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 950.18 kB
Formato Adobe PDF
950.18 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/972452
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? ND
social impact