The advanced source of Gamma-ray photons to be built in Bucharest (Romania), as part of the ELI-NP European Research Infrastructure, will generate photons by Compton back-scattering in the collision between a multi-bunch electron beam and a high intensity recirculated laser pulse. An S-Band photoinjector and the following C-band Linac at a maximum energy of 720MeV, under construction by an European consortium (EurogammaS) led by INFN, will operate at 100Hz repetition rate with trains of 32 electron bunches, separated by 16ns and a 250pC nominal charge. The different BPMs and current transformers used to measure transverse beam position and charge along the LINAC are described. Design criteria, production status and bench test results of the charge and position pickups are reported in the paper, together with the related data acquisition systems.

Beam diagnostics for charge and position measurements in ELI-NP GBS / Franzini, G.; Cioeta, Fara; Coiro, O.; Pellegrini, D.; A., Stella; M., Serio; Variola, A.; Mostacci, Andrea; Tocci, S.. - ELETTRONICO. - (2016), pp. 682-685. (Intervento presentato al convegno IBIC 2016 tenutosi a Barcelona, Spain nel 7-9 Settembre 2016) [10.18429/JACoW-IBIC2016-WEPG25].

Beam diagnostics for charge and position measurements in ELI-NP GBS

Franzini, G.;CIOETA, Fara;MOSTACCI, Andrea;
2016

Abstract

The advanced source of Gamma-ray photons to be built in Bucharest (Romania), as part of the ELI-NP European Research Infrastructure, will generate photons by Compton back-scattering in the collision between a multi-bunch electron beam and a high intensity recirculated laser pulse. An S-Band photoinjector and the following C-band Linac at a maximum energy of 720MeV, under construction by an European consortium (EurogammaS) led by INFN, will operate at 100Hz repetition rate with trains of 32 electron bunches, separated by 16ns and a 250pC nominal charge. The different BPMs and current transformers used to measure transverse beam position and charge along the LINAC are described. Design criteria, production status and bench test results of the charge and position pickups are reported in the paper, together with the related data acquisition systems.
2016
IBIC 2016
ELI-NP GBS
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Beam diagnostics for charge and position measurements in ELI-NP GBS / Franzini, G.; Cioeta, Fara; Coiro, O.; Pellegrini, D.; A., Stella; M., Serio; Variola, A.; Mostacci, Andrea; Tocci, S.. - ELETTRONICO. - (2016), pp. 682-685. (Intervento presentato al convegno IBIC 2016 tenutosi a Barcelona, Spain nel 7-9 Settembre 2016) [10.18429/JACoW-IBIC2016-WEPG25].
File allegati a questo prodotto
File Dimensione Formato  
Franzini_beam_2016.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 868.15 kB
Formato Adobe PDF
868.15 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/972446
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact