We read with great interest the article by Battersby et al. [1] about the impairment of surgical knot quality due to double gloving. The practice to wearing two pairs of gloves during surgical procedures to reduce the risks of exposure to patient’s blood and transmission of infectious organisms has been recommended worldwide, by several healthcare authorities, also on the basis of a Cochrane review showing the absence of compromised dexterity as a result of double gloving [2]. The study performed by Battersby and Colleagues clearly shows that double gloving reduces the quality of surgical knots by 24%, no matter the suture type used. A wider reduction of knot quality (50%) was noted with 4.0 sutures. These results question the safety of surgical knots tied wearing double gloves and, as a consequence, push surgeons to consider other precautions to reduce bloody contamination during surgery ...

Needlestick injuries, glove perforation and round-tipped blunt needles / Mingoli, Andrea; Brachini, Gioia; Sgarzini, Giovanna; Binda, Barbara; Zambon, Martina. - In: WORLD JOURNAL OF SURGERY. - ISSN 0364-2313. - STAMPA. - 41:9(2017), pp. 2413-2413. [10.1007/s00268-017-3941-7]

Needlestick injuries, glove perforation and round-tipped blunt needles

MINGOLI, Andrea
;
BRACHINI, GIOIA;SGARZINI, GIOVANNA;BINDA, BARBARA;ZAMBON, MARTINA
2017

Abstract

We read with great interest the article by Battersby et al. [1] about the impairment of surgical knot quality due to double gloving. The practice to wearing two pairs of gloves during surgical procedures to reduce the risks of exposure to patient’s blood and transmission of infectious organisms has been recommended worldwide, by several healthcare authorities, also on the basis of a Cochrane review showing the absence of compromised dexterity as a result of double gloving [2]. The study performed by Battersby and Colleagues clearly shows that double gloving reduces the quality of surgical knots by 24%, no matter the suture type used. A wider reduction of knot quality (50%) was noted with 4.0 sutures. These results question the safety of surgical knots tied wearing double gloves and, as a consequence, push surgeons to consider other precautions to reduce bloody contamination during surgery ...
2017
Surgery
01 Pubblicazione su rivista::01f Lettera, Nota
Needlestick injuries, glove perforation and round-tipped blunt needles / Mingoli, Andrea; Brachini, Gioia; Sgarzini, Giovanna; Binda, Barbara; Zambon, Martina. - In: WORLD JOURNAL OF SURGERY. - ISSN 0364-2313. - STAMPA. - 41:9(2017), pp. 2413-2413. [10.1007/s00268-017-3941-7]
File allegati a questo prodotto
File Dimensione Formato  
Mingoli_Needlestick_2017.pdf

accesso aperto

Note: Articolo principale
Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 109.2 kB
Formato Adobe PDF
109.2 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/970844
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact