The space conditioning sector is one of the highest exergy consumers and least efficient from the point of view of primary-to-end-use matching. Exergy analysis can be considered as a reliable tool for analyzing and optimizing energy consumption related to building conditioning systems. The present study presents a comparative exergy analysis of the air conditioning system of the TOTAL S.A. offices located in Caracas, Venezuela to finally achieve a reduction of the global electric energy use of the considered building. Starting from the provided thermal cooling load, different possible cooling chains (primary-to-final energy conversion chain) are considered in order to locate the thermodynamically more efficient one from an exergetic point of view. The internal air handler unit, which provides for the cooled and dehumidified air to the building, is fed by the energy obtained from different possible converters of renewable energy primary sources. Specifically, solar and hybrid photovoltaic-thermal (PV/T) panels coupled with an absorption refrigeration machine and with an ejector refrigeration cycle are analyzed. The study that has been carried on leads to identify the most convenient matching between final use and primary sources allowing to substantially reduce the global non-renewable energy consumption of the considered building. Copyright © 2014 by ASME.

Exergy analysis and optimization of a building air conditioning system in tropical climate / Salazar, Ricardo; Sciubba, Enrico; Toro, Claudia. - 6A:(2014), p. V06AT07A016. (Intervento presentato al convegno ASME 2014 International Mechanical Engineering Congress and Exposition, IMECE 2014 tenutosi a Montreal; Canada nel 2014) [10.1115/IMECE2014-36764].

Exergy analysis and optimization of a building air conditioning system in tropical climate

SCIUBBA, Enrico;TORO, CLAUDIA
2014

Abstract

The space conditioning sector is one of the highest exergy consumers and least efficient from the point of view of primary-to-end-use matching. Exergy analysis can be considered as a reliable tool for analyzing and optimizing energy consumption related to building conditioning systems. The present study presents a comparative exergy analysis of the air conditioning system of the TOTAL S.A. offices located in Caracas, Venezuela to finally achieve a reduction of the global electric energy use of the considered building. Starting from the provided thermal cooling load, different possible cooling chains (primary-to-final energy conversion chain) are considered in order to locate the thermodynamically more efficient one from an exergetic point of view. The internal air handler unit, which provides for the cooled and dehumidified air to the building, is fed by the energy obtained from different possible converters of renewable energy primary sources. Specifically, solar and hybrid photovoltaic-thermal (PV/T) panels coupled with an absorption refrigeration machine and with an ejector refrigeration cycle are analyzed. The study that has been carried on leads to identify the most convenient matching between final use and primary sources allowing to substantially reduce the global non-renewable energy consumption of the considered building. Copyright © 2014 by ASME.
2014
ASME 2014 International Mechanical Engineering Congress and Exposition, IMECE 2014
Mechanical Engineering
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Exergy analysis and optimization of a building air conditioning system in tropical climate / Salazar, Ricardo; Sciubba, Enrico; Toro, Claudia. - 6A:(2014), p. V06AT07A016. (Intervento presentato al convegno ASME 2014 International Mechanical Engineering Congress and Exposition, IMECE 2014 tenutosi a Montreal; Canada nel 2014) [10.1115/IMECE2014-36764].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/970202
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact