Endovascular aortic aneurysm repair is an effective alternative to open surgical repair in high risk patient. Endotension is an unpredictable late and rare complication of EVAR. Clinical significance and choice of technique for treatment are controversial. At present, there are no cases of endotension-related aneurysmal sac rupture reported in literature, altough it is frequently associated with late surgical conversion. In this case report is described a case of a patient treated with a first generation Gore Excluder (TM) endograft for abdominal aortic aneurysm, with late aneurysmal sac enlargement without evidence of endoleak and subsequent contained rupture without anemia and shock. We have successfully treated the patient by endovascular procedure, through bilateral percutaneous femoral approach, with relining technique. Three years CT scan follow-up showed the endograft patency and size sac reduction.

Endotension-related aortic sac rupture treated by endograft relining / Filippi, Francesco; Stella, N.; Rizzo, Luigi; Taurino, Maurizio; Tirotti, Chiara. - In: VASCULAR. - ISSN 1708-5381. - 21:2(2013), pp. 113-115. [10.1177/1708538113478725]

Endotension-related aortic sac rupture treated by endograft relining

FILIPPI, Francesco;RIZZO, Luigi;TAURINO, Maurizio;TIROTTI, CHIARA
2013

Abstract

Endovascular aortic aneurysm repair is an effective alternative to open surgical repair in high risk patient. Endotension is an unpredictable late and rare complication of EVAR. Clinical significance and choice of technique for treatment are controversial. At present, there are no cases of endotension-related aneurysmal sac rupture reported in literature, altough it is frequently associated with late surgical conversion. In this case report is described a case of a patient treated with a first generation Gore Excluder (TM) endograft for abdominal aortic aneurysm, with late aneurysmal sac enlargement without evidence of endoleak and subsequent contained rupture without anemia and shock. We have successfully treated the patient by endovascular procedure, through bilateral percutaneous femoral approach, with relining technique. Three years CT scan follow-up showed the endograft patency and size sac reduction.
2013
rupture; aortic; relining; endograft; endotension
01 Pubblicazione su rivista::01a Articolo in rivista
Endotension-related aortic sac rupture treated by endograft relining / Filippi, Francesco; Stella, N.; Rizzo, Luigi; Taurino, Maurizio; Tirotti, Chiara. - In: VASCULAR. - ISSN 1708-5381. - 21:2(2013), pp. 113-115. [10.1177/1708538113478725]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/967635
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact