Reinforced concrete columns with non-ductile detailing typically exhibit a softening behavior characterized by severe degradation when subjected to cyclic lateral loads. Whether the response is brittle or ductile, shear failure occurs with an inclined through crack along which sliding occurs coupled with loss of horizontal and vertical load-bearing capacity of the member. The rapid loss of resistance after the peak strength is reached is because of one or more of the following local failure mechanisms: brittle failure of poorly confined concrete; buckling of longitudinal reinforcing bars because of lack of adequate transverse reinforcement or following opening of stirrups after spalling of cover concrete; bond failure. In this study, a modeling strategy to build a detailed 3D finite element model capable of capturing all of the above-mentioned local failure mechanisms is presented. In particular, a steel-concrete interface model for representing the interaction within the member between concrete core, cover and longitudinal and transverse reinforcement is proposed. Comparison with results of an experimental test of a shear-sensitive column demonstrates the effectiveness of the simulation up to failure of the element.

Failure simulation of shear-critical RC columns with non-ductile detailing under lateral load / Lucchini, Andrea; Franchin, Paolo; Kunnath, S.. - In: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS. - ISSN 0098-8847. - 46:5(2017), pp. 855-874. [10.1002/eqe.2836]

Failure simulation of shear-critical RC columns with non-ductile detailing under lateral load

LUCCHINI, Andrea;FRANCHIN, Paolo;
2017

Abstract

Reinforced concrete columns with non-ductile detailing typically exhibit a softening behavior characterized by severe degradation when subjected to cyclic lateral loads. Whether the response is brittle or ductile, shear failure occurs with an inclined through crack along which sliding occurs coupled with loss of horizontal and vertical load-bearing capacity of the member. The rapid loss of resistance after the peak strength is reached is because of one or more of the following local failure mechanisms: brittle failure of poorly confined concrete; buckling of longitudinal reinforcing bars because of lack of adequate transverse reinforcement or following opening of stirrups after spalling of cover concrete; bond failure. In this study, a modeling strategy to build a detailed 3D finite element model capable of capturing all of the above-mentioned local failure mechanisms is presented. In particular, a steel-concrete interface model for representing the interaction within the member between concrete core, cover and longitudinal and transverse reinforcement is proposed. Comparison with results of an experimental test of a shear-sensitive column demonstrates the effectiveness of the simulation up to failure of the element.
2017
3D finite element modeling; reinforced concrete member; shear-critical column; collapse simulation; steel-concrete interface model
01 Pubblicazione su rivista::01a Articolo in rivista
Failure simulation of shear-critical RC columns with non-ductile detailing under lateral load / Lucchini, Andrea; Franchin, Paolo; Kunnath, S.. - In: EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS. - ISSN 0098-8847. - 46:5(2017), pp. 855-874. [10.1002/eqe.2836]
File allegati a questo prodotto
File Dimensione Formato  
Luccini_Failure_2017.pdf

solo utenti autorizzati

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.4 MB
Formato Adobe PDF
2.4 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/966701
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact