The high brightness electron LINAC of the Compton Gamma Source at the ELI Nuclear Physics facility in Roma- nia is accelerating a train of 32 bunches with a nominal total charge of 250 pC and nominal spacing of 16 ns . To achieve the design gamma flux, all the bunches along the train must have the designed Twiss parameters. Beam sizes are mea- sured with optical transition radiation monitors, allowing a quadrupole scan for Twiss parameters measurements. Since focusing the whole bunch train on the screen may lead to permanent screen damage, we investigate non-conventional scans such as scans around a maximum of the beam size or scans with a controlled minimum spot size. This paper discusses the implementation issues of such a technique in the actual machine layout
Quadrupole scan emittance measurements for the ELI-NP compton gamma source / Rossi, A. R.; Bacci, A.; Drebot, I.; Serafini, L.; Mostacci, Andrea; Giribono, Anna; Chiadroni, E.; Vaccarezza, Cristina; Variola, A.; Petrillo, V.; Rossetti Conti, M.; Curatolo, C.; Cianchi, A.. - ELETTRONICO. - (2016), pp. 126-129. (Intervento presentato al convegno 7th International Particle Accelerator Conference, IPAC 2016 tenutosi a BEXCO Convention Center, kor nel 2016).
Quadrupole scan emittance measurements for the ELI-NP compton gamma source
MOSTACCI, Andrea;GIRIBONO, ANNA;Chiadroni, E.;VACCAREZZA, CRISTINA;
2016
Abstract
The high brightness electron LINAC of the Compton Gamma Source at the ELI Nuclear Physics facility in Roma- nia is accelerating a train of 32 bunches with a nominal total charge of 250 pC and nominal spacing of 16 ns . To achieve the design gamma flux, all the bunches along the train must have the designed Twiss parameters. Beam sizes are mea- sured with optical transition radiation monitors, allowing a quadrupole scan for Twiss parameters measurements. Since focusing the whole bunch train on the screen may lead to permanent screen damage, we investigate non-conventional scans such as scans around a maximum of the beam size or scans with a controlled minimum spot size. This paper discusses the implementation issues of such a technique in the actual machine layoutFile | Dimensione | Formato | |
---|---|---|---|
mopmb019.pdf
accesso aperto
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.5 MB
Formato
Adobe PDF
|
1.5 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.