CUORE is a cryogenic detector that will be operated at LNGS to search for neutrinoless double beta decay (0νββ) of 130Te. The detector installation was completed in summer 2016. Before the installation, several cold runs were done to test the cryogenic system performance. In the last cold run the base temperature of 6.3 mK was reached in stable condition. CUORE-0, a CUORE prototype, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach.
The CUORE cryostat and its bolometric detector / Santone, D.; Alduino, C.; Alfonso, K.; Artusa, D. R.; Iii, F. T. Avignone; Azzolini, O.; Banks, T. I.; Bari, G.; Beeman, J. W.; Bellini, Fabio; Bersani, A.; Biassoni, M.; Branca, A.; Brofferio, C.; Bucci, C.; Camacho, A.; Caminata, A.; Canonica, L.; Cao, X. G.; Capelli, S.; Cappelli, L.; Carbone, L.; Cardani, Laura; Carniti, P.; Casali, Nicola; Cassina, L.; Chiesa, D.; Chott, N.; Clemenza, M.; Copello, S.; Cosmelli, Carlo; Cremonesi, O.; Creswick, R. J.; Cushman, J. S.; D'Addabbo, Antonio; Dafinei, Ioan; Davis, C. J.; Dell'Oro, S.; Deninno, M. M.; Domizio, S. Di; Vacri, M. L. Di; Drobizhev, A.; Fang, D. Q.; Faverzani, M.; Fernandes, G.; Ferri, E.; Ferroni, Fernando; Fiorini, E.; Franceschi, M. A.; Freedman, S. J.; Fujikawa, B. K.; Giachero, A.; Gironi, L.; Giuliani, A.; Gladstone, L.; Gorla, P.; Gotti, C.; Gutierrez, T. D.; Haller, E. E.; Han, K.; Hansen, E.; Heeger, K. M.; Hennings Yeomans, R.; Hickerson, K. P.; Huang, H. Z.; Kadel, R.; Keppel, G.; Kolomensky, Y. u. G.; Leder, A.; Ligi, C.; Lim, K. E.; Liu, X.; Ma, Y. G.; Maino, M.; Marini, L.; MARTINEZ PEREZ, MARIA LUCIA; Maruyama, R. H.; Mei, Y.; Moggi, N.; Morganti, S.; Mosteiro, P. J.; Napolitano, T.; Nones, C.; Norman, E. B.; Novati, V.; Nucciotti, A.; O'Donnell, T.; Orio, Filippo; Ouellet, J. L.; Pagliarone, C. E.; Pallavicini, M.; Palmieri, V.; Pattavina, L.; Pavan, M.; Pessina, G.; Pettinacci, Valerio; Piperno, Gabriele; Pira, C.; Pirro, S.; Pozzi, S.; Previtali, E.; Rosenfeld, C.; Rusconi, C.; Sangiorgio, S.; Scielzo, N. D.; Singh, V.; Sisti, M.; Smith, A. R.; Taffarello, L.; Tenconi, M.; Terranova, F.; Tomei, C.; Trentalange, S.; Vignati, Marco; Wagaarachchi, S. L.; Wang, B. S.; Wang, H. W.; Wilson, J.; Winslow, L. A.; Wise, T.; Woodcraft, A.; Zanotti, L.; Zhang, G. Q.; Zhu, B. X.; Zimmermann, S.; Zucchelli, S.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 12:02(2017), pp. C02055-C02055. [10.1088/1748-0221/12/02/C02055]
The CUORE cryostat and its bolometric detector
BELLINI, Fabio;CARDANI, LAURA;CASALI, NICOLA;COSMELLI, Carlo;D'ADDABBO, ANTONIO;DAFINEI, Ioan;FERRONI, Fernando;MARTINEZ PEREZ, MARIA LUCIA;PETTINACCI, VALERIO;PIPERNO, GABRIELE;VIGNATI, Marco;
2017
Abstract
CUORE is a cryogenic detector that will be operated at LNGS to search for neutrinoless double beta decay (0νββ) of 130Te. The detector installation was completed in summer 2016. Before the installation, several cold runs were done to test the cryogenic system performance. In the last cold run the base temperature of 6.3 mK was reached in stable condition. CUORE-0, a CUORE prototype, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach.File | Dimensione | Formato | |
---|---|---|---|
Santone_The CUORE cryostat_2017.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
3.35 MB
Formato
Adobe PDF
|
3.35 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.