Purpose: The aim was to calibrate gamma cameras in the framework of the Italian multicentre study for lesion dosimetry in 223Ra therapy of bone metastases. Equipments of several manufacturers and different models were used. Methods: Eleven gamma cameras (3/8- and 5/8-inch crystal) were used, acquiring planar static images with double-peak (82 and 154. keV, 20% wide) and MEGP collimator. The sensitivity was measured in air, varying source-detector distance and source size. Transmission curves were measured, calculating the parameters used for attenuation/scatter correction with the pseudo-extrapolation number method, and assessing their variations with the source size. Results: Values of the calibration factor (geometric mean of both detector sensitivities) ranged from 41.1 to 113.9. cps/MBq. For the smallest source (diameter of 3.5. cm), the calibration factor decrease ranged from -30% to -4%, highlighting the importance of partial volume effects according to the equipment involved. The sensitivity variation with the source-detector distance, with respect to the 15. cm-value, reached 10% (in absolute value) in the range 5-30. cm, but fixing the distance between the two heads, the calibration factor variation with the distance from the midline was within 3.6%. Appreciable variation of the transmission curves with the source size were observed, examining the results obtained with six gamma cameras. Conclusion: Assessments of sensitivity and transmission curve variations with source size should be regularly implemented in calibration procedures. The results of this study represent a useful compendium to check the obtained calibrations for dosimetric purposes.
Gamma camera calibrations for the Italian multicentre study for lesion dosimetry in 223Ra therapy of bone metastases / Pacilio, M; Cassano, B; Pellegrini, Rosanna; Di Castro, Elisabetta; Zorz, A.; De Vincentis, Giuseppe; Ventroni, G.; Mango, L.; Giancola, S.; Ferrari, M.; Cremonesi, M; Bianchi, C.; Virotta, G.; Carbonini, C.; Cesana, P.; Fulcheri, C.; Reggioli, V.; Ricci, A.; Trevisiol, E.; Anglesio, S.; Pani, Roberto. - In: PHYSICA MEDICA. - ISSN 1120-1797. - STAMPA. - 41:(2017), pp. 117-123. [10.1016/j.ejmp.2017.04.019]
Gamma camera calibrations for the Italian multicentre study for lesion dosimetry in 223Ra therapy of bone metastases
PELLEGRINI, Rosanna;DI CASTRO, Elisabetta;DE VINCENTIS, Giuseppe;PANI, RobertoUltimo
2017
Abstract
Purpose: The aim was to calibrate gamma cameras in the framework of the Italian multicentre study for lesion dosimetry in 223Ra therapy of bone metastases. Equipments of several manufacturers and different models were used. Methods: Eleven gamma cameras (3/8- and 5/8-inch crystal) were used, acquiring planar static images with double-peak (82 and 154. keV, 20% wide) and MEGP collimator. The sensitivity was measured in air, varying source-detector distance and source size. Transmission curves were measured, calculating the parameters used for attenuation/scatter correction with the pseudo-extrapolation number method, and assessing their variations with the source size. Results: Values of the calibration factor (geometric mean of both detector sensitivities) ranged from 41.1 to 113.9. cps/MBq. For the smallest source (diameter of 3.5. cm), the calibration factor decrease ranged from -30% to -4%, highlighting the importance of partial volume effects according to the equipment involved. The sensitivity variation with the source-detector distance, with respect to the 15. cm-value, reached 10% (in absolute value) in the range 5-30. cm, but fixing the distance between the two heads, the calibration factor variation with the distance from the midline was within 3.6%. Appreciable variation of the transmission curves with the source size were observed, examining the results obtained with six gamma cameras. Conclusion: Assessments of sensitivity and transmission curve variations with source size should be regularly implemented in calibration procedures. The results of this study represent a useful compendium to check the obtained calibrations for dosimetric purposes.File | Dimensione | Formato | |
---|---|---|---|
Pacilio_Gamma_2017.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
404.1 kB
Formato
Adobe PDF
|
404.1 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.