Coccidiostats are synthetic drugs administered to animals, especially to poultry, to cure coccidiosis. In this paper, we present a selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze residues of five synthetic coccidiostats in eggs: clazuril, diclazuril, robenidine, nicarbazin, toltrazuril and its two metabolites. The extraction efficiency was evaluated by testing several solvents, pH, different volumes and time of extraction. The clean-up procedures were optimized using different solid phase extraction cartridges and different eluants. The chromatographic separation was achieved in reversed phase using a gradient of 0.1% formic acid in water and acetonitrile, whereas the MS detection was performed in negative electrospray ionization (ESI) for all the analytes, except for the robenidine. The developed method has been validated according to Commission Decision 2002/657/CE. The validation parameters, as linearity, precision, recovery, specificity, decision limit (CC alpha), detection capability (CC beta), and robustness have been determined. The proposed method resulted simple, fast, and suitable for screening and confirmation purposes.

Liquid chromatography tandem mass spectrometry analysis of synthetic coccidiostats in eggs / Buiarelli, Francesca; DI FILIPPO, Patrizia; Riccardi, Carmela; Pomata, Donatella; Giannetti, Luigi; Neri, Bruno; Rago, Daniela. - In: SEPARATIONS. - ISSN 2297-8739. - ELETTRONICO. - 4:2(2017). [10.3390/separations4020015]

Liquid chromatography tandem mass spectrometry analysis of synthetic coccidiostats in eggs

Buiarelli Francesca
;
Di Filippo Patrizia
;
Pomata Donatella
;
2017

Abstract

Coccidiostats are synthetic drugs administered to animals, especially to poultry, to cure coccidiosis. In this paper, we present a selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to analyze residues of five synthetic coccidiostats in eggs: clazuril, diclazuril, robenidine, nicarbazin, toltrazuril and its two metabolites. The extraction efficiency was evaluated by testing several solvents, pH, different volumes and time of extraction. The clean-up procedures were optimized using different solid phase extraction cartridges and different eluants. The chromatographic separation was achieved in reversed phase using a gradient of 0.1% formic acid in water and acetonitrile, whereas the MS detection was performed in negative electrospray ionization (ESI) for all the analytes, except for the robenidine. The developed method has been validated according to Commission Decision 2002/657/CE. The validation parameters, as linearity, precision, recovery, specificity, decision limit (CC alpha), detection capability (CC beta), and robustness have been determined. The proposed method resulted simple, fast, and suitable for screening and confirmation purposes.
2017
synthetic coccidiostats; eggs; mass spectrometry
01 Pubblicazione su rivista::01a Articolo in rivista
Liquid chromatography tandem mass spectrometry analysis of synthetic coccidiostats in eggs / Buiarelli, Francesca; DI FILIPPO, Patrizia; Riccardi, Carmela; Pomata, Donatella; Giannetti, Luigi; Neri, Bruno; Rago, Daniela. - In: SEPARATIONS. - ISSN 2297-8739. - ELETTRONICO. - 4:2(2017). [10.3390/separations4020015]
File allegati a questo prodotto
File Dimensione Formato  
Buiarelli_Liquid_2017.pdf

accesso aperto

Note: https://www.mdpi.com/2297-8739/4/2/15
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 659.25 kB
Formato Adobe PDF
659.25 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/952587
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact