Partial Discharges (PD) detection in HV components has shown to be a very powerful diagnostic tool. Anyway, also the acquisition of the same signals in simple insulations, like the dielectric liquids, may give additional information for maintenance of HV components in which they are employed, as in the case of liquid insulated transformers. Among the standardized electrical tests suggested for the insulating liquids, the breakdown voltage (IEC 60156) and partial discharges determination (IEC 61294TR) at power frequency are not basic material properties but test procedures intended to indicate the presence of contaminants such as water and solid suspended matter and the advisability of carrying out drying and filtration treatment. Nevertheless, the PD detection method for insulating liquids actually standardized is based on superseded circuitry and is only addressed to measure the PD Inception Voltages (PDIV). The present paper shows the state of art in PD measurements in dielectric liquids to be taken into account when revising the actual IEC 61294TR or preparing new international Standards (ASTM).

Standard evolution of Partial Discharge detection in dielectric liquids / Calcara, Luigi; Pompili, Massimo; Muzi, Francesco. - In: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. - ISSN 1070-9878. - STAMPA. - 24:1(2017), pp. 2-6. [10.1109/TDEI.2016.006499]

Standard evolution of Partial Discharge detection in dielectric liquids

CALCARA, Luigi;POMPILI, Massimo;MUZI, FRANCESCO
2017

Abstract

Partial Discharges (PD) detection in HV components has shown to be a very powerful diagnostic tool. Anyway, also the acquisition of the same signals in simple insulations, like the dielectric liquids, may give additional information for maintenance of HV components in which they are employed, as in the case of liquid insulated transformers. Among the standardized electrical tests suggested for the insulating liquids, the breakdown voltage (IEC 60156) and partial discharges determination (IEC 61294TR) at power frequency are not basic material properties but test procedures intended to indicate the presence of contaminants such as water and solid suspended matter and the advisability of carrying out drying and filtration treatment. Nevertheless, the PD detection method for insulating liquids actually standardized is based on superseded circuitry and is only addressed to measure the PD Inception Voltages (PDIV). The present paper shows the state of art in PD measurements in dielectric liquids to be taken into account when revising the actual IEC 61294TR or preparing new international Standards (ASTM).
2017
breakdown pulse burst discharges; insulating liquids; partial discharges; standardization; electrical and electronic engineering
01 Pubblicazione su rivista::01a Articolo in rivista
Standard evolution of Partial Discharge detection in dielectric liquids / Calcara, Luigi; Pompili, Massimo; Muzi, Francesco. - In: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. - ISSN 1070-9878. - STAMPA. - 24:1(2017), pp. 2-6. [10.1109/TDEI.2016.006499]
File allegati a questo prodotto
File Dimensione Formato  
Calcara_Standard-Evolution_2017.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 919.6 kB
Formato Adobe PDF
919.6 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/948564
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 30
social impact