Purpose. Use of microperimetry (Mp-1), correlating with Humphrey perimetry (30-2 program), in patients affected by primary open-angle glaucoma (POAG) with perimetric defects, in order to obtain an evaluation of the accuracy of the results obtained by Mp-1. Materials and Methods. In this study 40 eyes of 25 patients affected by POAG with perimetric defects were included. All patients underwent microperimetry test by Nidek Mp-1 (NAVIS software version 1.7.2, Nidek Technologies). Mean sensitivity values expressed in decibel (dB) of all tested dots and mean values for each quadrant obtained by microperimetric test were correlated with corresponding quadrants obtained by static perimetry analysis. Data were analyzed by Pearson’s correlation and Bland-Altman analysis. Results. Interpolated data showed that mean sensitivity values in all spots tested by Mp-1 (11.98 dB, SD 4.31) may be significantly correlated with mean total values obtained by Humphrey 30-2 perimetry (17.95, SD 4.32), with correlation coefficient of 0.556. Conclusions. Topographic visualization of the perimetric alteration by microperimetry allows retesting areas with reduced sensitivity which are topographically visualized and displayable on the ocular fundus examination, avoiding worsening of the functional defect by better modulation of the antiglaucoma therapy and therefore it allows better monitoring of the pathologic functional damage.

Fascicular visual field defects in open-angle glaucoma: evaluation with microperimetry / Arrico, Loredana; Giannotti, Rossella; Fratipietro, Manuela; Malagola, Romualdo. - In: JOURNAL OF OPHTHALMOLOGY. - ISSN 2090-004X. - ELETTRONICO. - 2016:(2016). [10.1155/2016/8274954]

Fascicular visual field defects in open-angle glaucoma: evaluation with microperimetry

ARRICO, Loredana
Primo
;
Rossella Giannotti
Secondo
;
Manuela Fratipietro
Penultimo
;
MALAGOLA, Romualdo
Ultimo
2016

Abstract

Purpose. Use of microperimetry (Mp-1), correlating with Humphrey perimetry (30-2 program), in patients affected by primary open-angle glaucoma (POAG) with perimetric defects, in order to obtain an evaluation of the accuracy of the results obtained by Mp-1. Materials and Methods. In this study 40 eyes of 25 patients affected by POAG with perimetric defects were included. All patients underwent microperimetry test by Nidek Mp-1 (NAVIS software version 1.7.2, Nidek Technologies). Mean sensitivity values expressed in decibel (dB) of all tested dots and mean values for each quadrant obtained by microperimetric test were correlated with corresponding quadrants obtained by static perimetry analysis. Data were analyzed by Pearson’s correlation and Bland-Altman analysis. Results. Interpolated data showed that mean sensitivity values in all spots tested by Mp-1 (11.98 dB, SD 4.31) may be significantly correlated with mean total values obtained by Humphrey 30-2 perimetry (17.95, SD 4.32), with correlation coefficient of 0.556. Conclusions. Topographic visualization of the perimetric alteration by microperimetry allows retesting areas with reduced sensitivity which are topographically visualized and displayable on the ocular fundus examination, avoiding worsening of the functional defect by better modulation of the antiglaucoma therapy and therefore it allows better monitoring of the pathologic functional damage.
2016
fascicular visual field defects; open-angle glaucoma; microperimetry
01 Pubblicazione su rivista::01a Articolo in rivista
Fascicular visual field defects in open-angle glaucoma: evaluation with microperimetry / Arrico, Loredana; Giannotti, Rossella; Fratipietro, Manuela; Malagola, Romualdo. - In: JOURNAL OF OPHTHALMOLOGY. - ISSN 2090-004X. - ELETTRONICO. - 2016:(2016). [10.1155/2016/8274954]
File allegati a questo prodotto
File Dimensione Formato  
Arrico_Fascicular visual field_2016.pdf

accesso aperto

Note: https://www.hindawi.com/journals/joph/2016/8274954/
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.86 MB
Formato Adobe PDF
2.86 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/939826
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact