This paper analyses the dynamic behaviour of a seismic isolation technology adopted for the foundations of the towers of two recent long-span bridges, consisting of a dissipative layer of granular soil placed at the contact of the foundation caisson with a group of foundation piles. The fundamental aspects of this isolation device is studied through a three-dimensional modified Newmark model that accounts for the multi-directionality of the seismic motion and includes a simplified description of the dynamic response of the superstructure. This simplified model is expressed in a rigorous non-dimensional formulation and is validated against the results of three-dimensional dynamic analysis of the soil-structure interaction for a specific case of a suspension bridge. Taking advantage of the non-dimensional formulation of the simplified dynamic model, a parametric study of general validity is carried out, that highlights the most significant factors influencing the performance of the dissipative device.
Predicting the Dynamic Response of Friction Dissipative Foundations Using a Modified Newmark Model / Gorini, DAVIDE NOE'; Callisto, Luigi. - In: PROCEDIA ENGINEERING. - ISSN 1877-7058. - ELETTRONICO. - 158:(2016), pp. 170-175. (Intervento presentato al convegno 6th Italian Conference of Researchers in Geotechnical Engineering, CNRIG 2016 tenutosi a Auditorium of Department of Arts of the Alma Mater Studiorum, ita nel 2016) [10.1016/j.proeng.2016.08.424].
Predicting the Dynamic Response of Friction Dissipative Foundations Using a Modified Newmark Model
GORINI, DAVIDE NOE';CALLISTO, Luigi
2016
Abstract
This paper analyses the dynamic behaviour of a seismic isolation technology adopted for the foundations of the towers of two recent long-span bridges, consisting of a dissipative layer of granular soil placed at the contact of the foundation caisson with a group of foundation piles. The fundamental aspects of this isolation device is studied through a three-dimensional modified Newmark model that accounts for the multi-directionality of the seismic motion and includes a simplified description of the dynamic response of the superstructure. This simplified model is expressed in a rigorous non-dimensional formulation and is validated against the results of three-dimensional dynamic analysis of the soil-structure interaction for a specific case of a suspension bridge. Taking advantage of the non-dimensional formulation of the simplified dynamic model, a parametric study of general validity is carried out, that highlights the most significant factors influencing the performance of the dissipative device.File | Dimensione | Formato | |
---|---|---|---|
Gorini_Predicting_2016.pdf
accesso aperto
Note: Articolo
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Creative commons
Dimensione
456.78 kB
Formato
Adobe PDF
|
456.78 kB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.