The aim of the study was to evaluate the diagnostic effectiveness of color Doppler ultrasound (CDUS) with superb microvascular imaging (SMI) compared to contrast-enhanced ultrasound (CEUS), computed tomography (CT) multislice angiography (64 slices), and angiography required for therapeutic reasons, for follow-up after endovascular aneurysm repair (EVAR).
Background: The aim of the study was to evaluate the diagnostic effectiveness of color Doppler ultrasound (CDUS) with superb microvascular imaging (SMI) compared to contrast-enhanced ultrasound (CEUS), computed tomography (CT) multislice angiography (64 slices), and angiography required for therapeutic reasons, for follow-up after endovascular aneurysm repair (EVAR). Methods: From March 2014 to May 2015, 57 patients treated with EVAR were evaluated with CT, CEUS, CDUS, SMI, and angiography in cases requiring treatment. Evaluation included sac diameter, stent-graft integrity, identification, and classification of endoleaks. Sensitivity, specificity, accuracy, and negative and positive predictive values were evaluated for each modality of endoleak identification. Results: Eight endoleaks (16.3%), all type II, were documented. Sensitivity of CT, CEUS, CDUS and SMI was 88%, 100%, 63%, and 75%, respectively. Specificity of CT, CEUS, CDUS, and SMI was 100%, 100%, 96%, and 98%, respectively With SMI, CDUS sensitivity significantly increased, whereas specificity did not register great differences. Conclusions: SMI was more accurate than CDUS but less accurate than CEUS and CT to identify endoleaks after EVAR. SMI could be concretely used in the follow-up phase to increase CDUS accuracy especially in patients who cannot be studied with CEUS or CT.
Color doppler ultrasound with superb microvascular imaging compared to contrast-enhanced ultrasound and computed tomography angiography to identify and classify endoleaks in patients undergoing EVAR / Cantisani, Vito; David, Emanuele; Ferrari, Donatella; Fanelli, Fabrizio; DI MARZO, Luca; Catalano, Carlo; Benedetto, Filippo; Spinelli, Domenico; Katsargyris, Athanasios; Blandino, Alfredo; Ascenti, Giorgio; D'Ambrosio, Ferdinando. - In: ANNALS OF VASCULAR SURGERY. - ISSN 0890-5096. - 40:April(2017), pp. 136-145. [10.1016/j.avsg.2016.06.038]
Color doppler ultrasound with superb microvascular imaging compared to contrast-enhanced ultrasound and computed tomography angiography to identify and classify endoleaks in patients undergoing EVAR
CANTISANI, VITOPrimo
;David, EmanueleSecondo
;FERRARI , DONATELLA;FANELLI, Fabrizio;DI MARZO, Luca;CATALANO, Carlo;D'AMBROSIO, FerdinandoUltimo
2017
Abstract
Background: The aim of the study was to evaluate the diagnostic effectiveness of color Doppler ultrasound (CDUS) with superb microvascular imaging (SMI) compared to contrast-enhanced ultrasound (CEUS), computed tomography (CT) multislice angiography (64 slices), and angiography required for therapeutic reasons, for follow-up after endovascular aneurysm repair (EVAR). Methods: From March 2014 to May 2015, 57 patients treated with EVAR were evaluated with CT, CEUS, CDUS, SMI, and angiography in cases requiring treatment. Evaluation included sac diameter, stent-graft integrity, identification, and classification of endoleaks. Sensitivity, specificity, accuracy, and negative and positive predictive values were evaluated for each modality of endoleak identification. Results: Eight endoleaks (16.3%), all type II, were documented. Sensitivity of CT, CEUS, CDUS and SMI was 88%, 100%, 63%, and 75%, respectively. Specificity of CT, CEUS, CDUS, and SMI was 100%, 100%, 96%, and 98%, respectively With SMI, CDUS sensitivity significantly increased, whereas specificity did not register great differences. Conclusions: SMI was more accurate than CDUS but less accurate than CEUS and CT to identify endoleaks after EVAR. SMI could be concretely used in the follow-up phase to increase CDUS accuracy especially in patients who cannot be studied with CEUS or CT.File | Dimensione | Formato | |
---|---|---|---|
Cantisani_Color-doppler_2017.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
4.38 MB
Formato
Adobe PDF
|
4.38 MB | Adobe PDF | Contatta l'autore |
Cantisani_postprint_Color-doppler_2017.pdf
accesso aperto
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
Creative commons
Dimensione
9.25 MB
Formato
Adobe PDF
|
9.25 MB | Adobe PDF |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.