Purpose. To compare sonohysterosalpingography (sono-HSG) with foam instillation (HyFoSy) versus saline solution (HyCoSy) in the evaluation of tubal patency. Methods. We prospectively enrolled 37 infertile women, scheduled for laparoscopy. The women were randomized into two groups: HyFoSy (group I) and HyCoSy (group II). The patients of both groups underwent laparoscopy with dye test. We assessed the diagnostic performance (sensitivity, specificity, and overall accuracy) of HyFoSy and HyCoSy, compared with laparoscopy and dye test, in the assessment of tubal patency. Results. Sono-HSG findings in tubal patency assessment obtained in the HyFoSy group were concordant with laparoscopic results in 94.4% of cases, with a sensitivity of 87.5% and a specificity of 100%, whereas in the HyCoSy group, concordance occurred in only 57.8% of examinations, with a sensitivity of 50% and a specificity of 66.6%. Conclusions. HyFoSy allows a more accurate diagnosis of tubal patency compared with HyCoSy.
Sonohysterosalpingography: Comparison of foam and saline solution / Piccioni, Maria Grazia; Riganelli, Lucia; Filippi, Valentina; Fuggetta, Eliana; Colagiovanni, Vanessa; Imperiale, Ludovica; Caccetta, Jlenia; BENEDETTI PANICI, Pierluigi; Porpora, Maria Grazia. - In: JOURNAL OF CLINICAL ULTRASOUND. - ISSN 0091-2751. - ELETTRONICO. - 45:2(2017), pp. 67-71. [10.1002/jcu.22412]
Sonohysterosalpingography: Comparison of foam and saline solution
PICCIONI, Maria Grazia;RIGANELLI, LUCIA
;FILIPPI, VALENTINA;FUGGETTA, ELIANA;COLAGIOVANNI, VANESSA;IMPERIALE, LUDOVICA;CACCETTA, JLENIA;BENEDETTI PANICI, PIERLUIGI;PORPORA, Maria Grazia
2017
Abstract
Purpose. To compare sonohysterosalpingography (sono-HSG) with foam instillation (HyFoSy) versus saline solution (HyCoSy) in the evaluation of tubal patency. Methods. We prospectively enrolled 37 infertile women, scheduled for laparoscopy. The women were randomized into two groups: HyFoSy (group I) and HyCoSy (group II). The patients of both groups underwent laparoscopy with dye test. We assessed the diagnostic performance (sensitivity, specificity, and overall accuracy) of HyFoSy and HyCoSy, compared with laparoscopy and dye test, in the assessment of tubal patency. Results. Sono-HSG findings in tubal patency assessment obtained in the HyFoSy group were concordant with laparoscopic results in 94.4% of cases, with a sensitivity of 87.5% and a specificity of 100%, whereas in the HyCoSy group, concordance occurred in only 57.8% of examinations, with a sensitivity of 50% and a specificity of 66.6%. Conclusions. HyFoSy allows a more accurate diagnosis of tubal patency compared with HyCoSy.File | Dimensione | Formato | |
---|---|---|---|
Piccioni_Sonohysterosalpingography_2017.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
154.67 kB
Formato
Adobe PDF
|
154.67 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.