We present a novel system for the markerless shape analysis of bicipital contraction. The study of the soft tissue deformation due to the biceps muscular activity is achieved by analysing video sequences obtained from a RGB-D sensor and applying geometric morphometrics and parallel transport algorithms. In particular, we tested for differences between genders in soft tissue deformation during isometric contraction. Tests on 20 subjects (10 males, 10 females) in biceps brachii isometric contraction have been performed. The obtained results, in terms of size and shape deformations, are in accordance with biomechanical and physiological studies. The performance of the proposed method is particularly encouraging for its application to elderlies, in the bio-medical investigations as well as in rehabilitation of the upper limb.

Shape analysis of bicipital contraction by means of RGB-D sensor, parallel transport and trajectory analysis / Goffredo, Michela; Piras, Paolo; Varano, V.; Gabriele, S.; D’Anna, C.; Conforto, S.. - 57:(2016), pp. 628-633. (Intervento presentato al convegno 14th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2016 tenutosi a Paphos, CYPRUS nel 2016) [10.1007/978-3-319-32703-7_121].

Shape analysis of bicipital contraction by means of RGB-D sensor, parallel transport and trajectory analysis

PIRAS, PAOLO;
2016

Abstract

We present a novel system for the markerless shape analysis of bicipital contraction. The study of the soft tissue deformation due to the biceps muscular activity is achieved by analysing video sequences obtained from a RGB-D sensor and applying geometric morphometrics and parallel transport algorithms. In particular, we tested for differences between genders in soft tissue deformation during isometric contraction. Tests on 20 subjects (10 males, 10 females) in biceps brachii isometric contraction have been performed. The obtained results, in terms of size and shape deformations, are in accordance with biomechanical and physiological studies. The performance of the proposed method is particularly encouraging for its application to elderlies, in the bio-medical investigations as well as in rehabilitation of the upper limb.
2016
14th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2016
geometric morphometrics; muscular contraction; parallel transport; rgb-d sensor; soft tissue deformation; biomedical engineering; bioengineering
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Shape analysis of bicipital contraction by means of RGB-D sensor, parallel transport and trajectory analysis / Goffredo, Michela; Piras, Paolo; Varano, V.; Gabriele, S.; D’Anna, C.; Conforto, S.. - 57:(2016), pp. 628-633. (Intervento presentato al convegno 14th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2016 tenutosi a Paphos, CYPRUS nel 2016) [10.1007/978-3-319-32703-7_121].
File allegati a questo prodotto
File Dimensione Formato  
Goffredo_Shape_2016.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 905.36 kB
Formato Unknown
905.36 kB Unknown   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/898181
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact