Remote Health Monitoring (RHM) applications encounter limitations from technological front viz. bandwidth, storage and transmission time and the medical science front i.e. usage of 2-3 lead systems instead of the standard 12-lead (S12) system. Technological limitations constraint the number of leads to 2-3 while cardiologists accustomed with 12-Lead ECG may find these 2-3 lead systems insufficient for diagnosis. Thus, the aforementioned limitations pose self-contradicting challenges for RHM. A personalized reduced 2/3 lead system is required which can offer equivalent information as contained in S12 system, so as to accurately reconstruct S12 system from reduced lead system for diagnosis. In this paper, we propose a personalized reduced 3-lead (R3L) system formation methodology which employs principal component analysis, thereby, reducing redundancy and increasing SNR ratio, hence, making it suitable for wireless transmission. Accurate S12 system is made available using personalized lead reconstruction methodology, thus addressing medical constraints. Mean R2 statistics values obtained for reconstruction of S12 system from the proposed R3L system using PhysioNet’s PTB and TWA databases were 95.63% and 96.37% respectively. To substantiate the superior diagnostic quality of reconstructed leads, root mean square error (RMSE) metrics obtained upon comparing the ECG features extracted from the original and reconstructed leads, using our recently proposed Time Domain Morphology and Gradient (TDMG) algorithm, have been analyzed and discussed. The proposed system does not require any extra electrode or modification in placement positions and hence, can readily find application in computerized ECG machines.

Personalized reduced 3-lead system formation methodology for Remote Health Monitoring applications and reconstruction of standard 12-lead system / Maheshwari, S; Acharyya, A; Schiariti, Michele Salvatore Maria; Puddu, Paolo Emilio. - In: INTERNATIONAL ARCHIVES OF MEDICINE. - ISSN 1755-7682. - ELETTRONICO. - 8:1(2015). [10.3823/1661]

Personalized reduced 3-lead system formation methodology for Remote Health Monitoring applications and reconstruction of standard 12-lead system

SCHIARITI, Michele Salvatore Maria;PUDDU, Paolo Emilio
2015

Abstract

Remote Health Monitoring (RHM) applications encounter limitations from technological front viz. bandwidth, storage and transmission time and the medical science front i.e. usage of 2-3 lead systems instead of the standard 12-lead (S12) system. Technological limitations constraint the number of leads to 2-3 while cardiologists accustomed with 12-Lead ECG may find these 2-3 lead systems insufficient for diagnosis. Thus, the aforementioned limitations pose self-contradicting challenges for RHM. A personalized reduced 2/3 lead system is required which can offer equivalent information as contained in S12 system, so as to accurately reconstruct S12 system from reduced lead system for diagnosis. In this paper, we propose a personalized reduced 3-lead (R3L) system formation methodology which employs principal component analysis, thereby, reducing redundancy and increasing SNR ratio, hence, making it suitable for wireless transmission. Accurate S12 system is made available using personalized lead reconstruction methodology, thus addressing medical constraints. Mean R2 statistics values obtained for reconstruction of S12 system from the proposed R3L system using PhysioNet’s PTB and TWA databases were 95.63% and 96.37% respectively. To substantiate the superior diagnostic quality of reconstructed leads, root mean square error (RMSE) metrics obtained upon comparing the ECG features extracted from the original and reconstructed leads, using our recently proposed Time Domain Morphology and Gradient (TDMG) algorithm, have been analyzed and discussed. The proposed system does not require any extra electrode or modification in placement positions and hence, can readily find application in computerized ECG machines.
2015
reduced lead system; standard 12-lead system; PCA; lead recontruction; remote health monitoring
01 Pubblicazione su rivista::01a Articolo in rivista
Personalized reduced 3-lead system formation methodology for Remote Health Monitoring applications and reconstruction of standard 12-lead system / Maheshwari, S; Acharyya, A; Schiariti, Michele Salvatore Maria; Puddu, Paolo Emilio. - In: INTERNATIONAL ARCHIVES OF MEDICINE. - ISSN 1755-7682. - ELETTRONICO. - 8:1(2015). [10.3823/1661]
File allegati a questo prodotto
File Dimensione Formato  
Maheshwari_Remote-health-monitoring_2015.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 4.88 MB
Formato Adobe PDF
4.88 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/896188
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? ND
social impact