BACKGROUND: Over the last two decades the interest on patent foramen ovale (PFO) as a cause of cardioembolism in cryptogenic stroke has tremendously increased, thanks to the availability of better techniques to diagnose cardiac right-to-left shunt by ultrasounds and of percutaneous means of PFO treatment with interventional techniques. Many studies have been published that have attempted to define diagnostic methodology, prognosis, and optimal treatment (pharmacological or percutaneous closure) of PFO patients with cryptogenic stroke. Unfortunately, even today, definitive evidence is still lacking, and clinical management is not consistent among cardiologists. AIMS: This review aims to evaluate the role of PFO in cryptogenic stroke, the diagnostic accuracy of transcranial Doppler, contrast transthoracic and transesophageal echocardiography in the diagnosis of left-fright shunt and PFO; and discuss the indications to medical treatment and percutaneous closure of PFO. METHODS: All studies published in the literature on PFO and cryptogenic stroke are considered and discussed. RESULTS: We define an appropriate diagnostic and clinical management of PFO patients with cryptogenic stroke. CONCLUSION: After many years of interest on PFO and many concluded studies, there are still no definitive data. However, we are on good track for an appropriate management of PFO patients and cryptogenic strok

Patent foramen ovale and cryptogenic stroke. from studies to clinical practice. position paper of the italian chapter, international society cardiovascular ultrasound / Savino, K; Maiello, M.; Pelliccia, Francesco; Ambrosio, G.; Palmiero, P.. - In: INTERNATIONAL JOURNAL OF CLINICAL PRACTICE. - ISSN 1368-5031. - STAMPA. - 70:8(2016), pp. 641-648. [10.1111/ijcp.12842]

Patent foramen ovale and cryptogenic stroke. from studies to clinical practice. position paper of the italian chapter, international society cardiovascular ultrasound

PELLICCIA, FRANCESCO;
2016

Abstract

BACKGROUND: Over the last two decades the interest on patent foramen ovale (PFO) as a cause of cardioembolism in cryptogenic stroke has tremendously increased, thanks to the availability of better techniques to diagnose cardiac right-to-left shunt by ultrasounds and of percutaneous means of PFO treatment with interventional techniques. Many studies have been published that have attempted to define diagnostic methodology, prognosis, and optimal treatment (pharmacological or percutaneous closure) of PFO patients with cryptogenic stroke. Unfortunately, even today, definitive evidence is still lacking, and clinical management is not consistent among cardiologists. AIMS: This review aims to evaluate the role of PFO in cryptogenic stroke, the diagnostic accuracy of transcranial Doppler, contrast transthoracic and transesophageal echocardiography in the diagnosis of left-fright shunt and PFO; and discuss the indications to medical treatment and percutaneous closure of PFO. METHODS: All studies published in the literature on PFO and cryptogenic stroke are considered and discussed. RESULTS: We define an appropriate diagnostic and clinical management of PFO patients with cryptogenic stroke. CONCLUSION: After many years of interest on PFO and many concluded studies, there are still no definitive data. However, we are on good track for an appropriate management of PFO patients and cryptogenic strok
2016
atrial septal aneurysm; transient ischemic attack; recurrent cerebrovascular events; health-care professionals; to-left shunt; percutaneous closure; paradoxical embolism; transesophageal echocardiography; secondary prevention; cerebral-ischemia
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
Patent foramen ovale and cryptogenic stroke. from studies to clinical practice. position paper of the italian chapter, international society cardiovascular ultrasound / Savino, K; Maiello, M.; Pelliccia, Francesco; Ambrosio, G.; Palmiero, P.. - In: INTERNATIONAL JOURNAL OF CLINICAL PRACTICE. - ISSN 1368-5031. - STAMPA. - 70:8(2016), pp. 641-648. [10.1111/ijcp.12842]
File allegati a questo prodotto
File Dimensione Formato  
Savino_Patent_2016.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 212.91 kB
Formato Adobe PDF
212.91 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/893585
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 4
social impact