Vitrification is a new method that has been recently introduced in Assisted Reproduction Technique programs. The aim of this study was to design a new medium similar to normal human seminal fluid (SF), formulation artificial seminal fluid (ASF), and to compare the cryoprotective potency of this medium with SF and human tubal fluid (HTF) medium. Thirty normal ejaculates were processed with the swim-up technique and sperm suspensions were divided into four aliquots: (i) fresh sample (control); (ii) vitrification in HTF medium supplemented with 5 mg/mL human serum albumin and 0.25 mol sucrose (Vit HTF); (iii) vitrification with patients' SF (Vit SF); and (iv) vitrification in ASF (Vit ASF). After warming, sperm parameters of motility, viability, and morphology were analyzed using WHO criteria. Also, sperm pellets were fixed in 2.5% glutaraldehyde and processed for scanning electron microscopy and transmission electron microscopy observations. The results showed that progressive motility (46.09 ± 10.33 vs. 36.80 ± 13.75), grade A motility (36.59 ± 11.40 vs. 16.41 ± 11.24), and normal morphology (18.74 ± 8.35 vs. 11.85 ± 5.84) and viability (68.22 ± 10.83 vs. 60.86 ± 11.72) of spermatozoa were significantly higher in Vit ASF than in Vit HTF. All parameters were better in Vit ASF than in Vit SF, but only viability was significantly different (p = 0.006). After cryopreservation, deep invagination in cytoplasm and mechanically weak point sites and folded tail were commonly observed. But, this phenomenon was more significant in Vit HTF and Vit SF than in ASF (p < 0.05). In transmission electron microscopy evaluation, acrosome damage, plasma membrane loss, chromatin vacuolation, and disruption of mitochondria arrangement and structures were observed in all vitrified groups. Adherence of several tail sections together was also seen in all cryo groups. But this was seen more in Vit HTF and Vit SF than in ASF (p < 0.05). In conclusion, vitrification of human spermatozoa with ASF can effectively preserve the quality of sperm motility in comparison with Vit HTF. © 2016 American Society of Andrology and European Academy of Andrology.

Cryoprotectant-free vitrification of human spermatozoa in new artificial seminal fluid / Agha Rahimi, A.; Khalili, M. A.; Nottola, Stefania Annarita; Miglietta, Selenia; Moradi, A.. - In: ANDROLOGY. - ISSN 2047-2919. - STAMPA. - 4:6(2016), pp. 1037-1044. [doi: 10.1111/andr.12212]

Cryoprotectant-free vitrification of human spermatozoa in new artificial seminal fluid

NOTTOLA, Stefania Annarita;MIGLIETTA, SELENIA;
2016

Abstract

Vitrification is a new method that has been recently introduced in Assisted Reproduction Technique programs. The aim of this study was to design a new medium similar to normal human seminal fluid (SF), formulation artificial seminal fluid (ASF), and to compare the cryoprotective potency of this medium with SF and human tubal fluid (HTF) medium. Thirty normal ejaculates were processed with the swim-up technique and sperm suspensions were divided into four aliquots: (i) fresh sample (control); (ii) vitrification in HTF medium supplemented with 5 mg/mL human serum albumin and 0.25 mol sucrose (Vit HTF); (iii) vitrification with patients' SF (Vit SF); and (iv) vitrification in ASF (Vit ASF). After warming, sperm parameters of motility, viability, and morphology were analyzed using WHO criteria. Also, sperm pellets were fixed in 2.5% glutaraldehyde and processed for scanning electron microscopy and transmission electron microscopy observations. The results showed that progressive motility (46.09 ± 10.33 vs. 36.80 ± 13.75), grade A motility (36.59 ± 11.40 vs. 16.41 ± 11.24), and normal morphology (18.74 ± 8.35 vs. 11.85 ± 5.84) and viability (68.22 ± 10.83 vs. 60.86 ± 11.72) of spermatozoa were significantly higher in Vit ASF than in Vit HTF. All parameters were better in Vit ASF than in Vit SF, but only viability was significantly different (p = 0.006). After cryopreservation, deep invagination in cytoplasm and mechanically weak point sites and folded tail were commonly observed. But, this phenomenon was more significant in Vit HTF and Vit SF than in ASF (p < 0.05). In transmission electron microscopy evaluation, acrosome damage, plasma membrane loss, chromatin vacuolation, and disruption of mitochondria arrangement and structures were observed in all vitrified groups. Adherence of several tail sections together was also seen in all cryo groups. But this was seen more in Vit HTF and Vit SF than in ASF (p < 0.05). In conclusion, vitrification of human spermatozoa with ASF can effectively preserve the quality of sperm motility in comparison with Vit HTF. © 2016 American Society of Andrology and European Academy of Andrology.
2016
artificial seminal fluid; human spermatozoa; seminal fluid; vitrification
01 Pubblicazione su rivista::01a Articolo in rivista
Cryoprotectant-free vitrification of human spermatozoa in new artificial seminal fluid / Agha Rahimi, A.; Khalili, M. A.; Nottola, Stefania Annarita; Miglietta, Selenia; Moradi, A.. - In: ANDROLOGY. - ISSN 2047-2919. - STAMPA. - 4:6(2016), pp. 1037-1044. [doi: 10.1111/andr.12212]
File allegati a questo prodotto
File Dimensione Formato  
Agha-Rahimi_Cryoprotectant-free_2016.pdf

accesso aperto

Note: articolo principale
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 2.23 MB
Formato Adobe PDF
2.23 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/891867
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 22
social impact