OBJECTIVES: To compare the safety and efficacy of the Axxess™ biolimus-eluting stent with the second-generation drug-eluting stent (DES) in the treatment of bifurcation lesions. BACKGROUND: The Axxess™ is a dedicated bifurcation stent, designed to cover the lesion at the carina level. METHODS: Between April 2012 and August 2014, 165 patients with de novo bifurcation lesions were treated with the Axxess™ stent (Axxess group). A propensity-score matched group of 165 patients treated with DES in the same period was selected (Control group). The primary objectives were (1) the procedural complication rate, including side branch (SB) occlusion and trouble in SB access after main vessel stenting; and (2) the device, the angiographic, and the procedural success rate. RESULTS: Procedural complications occurred in 1 patient (0.6%) in the Axxess group and in 20 patients (12%) in the Control group (OR = 0.03; 95% confidence interval 0.005-0.27; P < 0.001). Device success was obtained in 164 (99.5%) patients in the Axxess group and in all in the Control group (P = 1.00). Angiographic success was obtained in all patients. Inaccurate Axxess™ stent position occurred in 21 (13%) patients, and was more often associated with moderate-to-severe calcifications and distal lesion site. Procedural success was obtained in 91.5% patients in the Axxess group and in 90% patients in the Control group (P = 0.72). CONCLUSIONS: The present registry suggests that the Axxess™ stent (1) may represent a valid alternative approach for the treatment of bifurcation lesions and (2) should be avoided in moderate-to-severe calcifications and/or in distal lesions.
Coronary artery bifurcation narrowing treated by axxess stent implantation. the CARINAX registry / Briguori, Carlo; Donahue, Michael Edward; Visconti, Gabriella; Focaccio, Amelia; Pennacchi, Mauro; Lucisano, Luigi; Stio, Rocco Edoardo; Mancone, Massimo; Calcagno, Simone; Di Palma, Vito; Labalestra, Nicola; Signoriello, Giuseppe; Sardella, Gennaro. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - ELETTRONICO. - 89:4(2017), pp. E112-E123. [10.1002/ccd.26659]
Coronary artery bifurcation narrowing treated by axxess stent implantation. the CARINAX registry
DONAHUE, MICHAEL EDWARD;PENNACCHI, MAURO;LUCISANO, LUIGI;STIO, ROCCO EDOARDO;MANCONE, Massimo;CALCAGNO, SIMONE;SARDELLA, Gennaro
2017
Abstract
OBJECTIVES: To compare the safety and efficacy of the Axxess™ biolimus-eluting stent with the second-generation drug-eluting stent (DES) in the treatment of bifurcation lesions. BACKGROUND: The Axxess™ is a dedicated bifurcation stent, designed to cover the lesion at the carina level. METHODS: Between April 2012 and August 2014, 165 patients with de novo bifurcation lesions were treated with the Axxess™ stent (Axxess group). A propensity-score matched group of 165 patients treated with DES in the same period was selected (Control group). The primary objectives were (1) the procedural complication rate, including side branch (SB) occlusion and trouble in SB access after main vessel stenting; and (2) the device, the angiographic, and the procedural success rate. RESULTS: Procedural complications occurred in 1 patient (0.6%) in the Axxess group and in 20 patients (12%) in the Control group (OR = 0.03; 95% confidence interval 0.005-0.27; P < 0.001). Device success was obtained in 164 (99.5%) patients in the Axxess group and in all in the Control group (P = 1.00). Angiographic success was obtained in all patients. Inaccurate Axxess™ stent position occurred in 21 (13%) patients, and was more often associated with moderate-to-severe calcifications and distal lesion site. Procedural success was obtained in 91.5% patients in the Axxess group and in 90% patients in the Control group (P = 0.72). CONCLUSIONS: The present registry suggests that the Axxess™ stent (1) may represent a valid alternative approach for the treatment of bifurcation lesions and (2) should be avoided in moderate-to-severe calcifications and/or in distal lesions.File | Dimensione | Formato | |
---|---|---|---|
Briguori_Coronary_2016.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
357.95 kB
Formato
Adobe PDF
|
357.95 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.