Intraoperative sentinel node detection by an innovative imaging probe. Campisi C, Soluri A, Stella S, Valenti G, Scopinaro F. SourceInstitute of Biomedical Technologies, National Research Council, Rome. campisi@itbm.rm.cnr.it Abstract Intraoperative tumor detection has been used in many applications, and today the sentinel node technique is a widely employed surgical procedure in breast cancer. Different detector systems are employed but several problems have been reported in clinical practice, in particular the difficulty to accurately detect the sentinel node within the axillary soft tissue. The problem is even greater for abdominal and thoracic tumors. We propose an innovative Imaging Probe (IP) able to visualize on a monitor the primary tumor and secondary lesions if appropriately radiolabeled. The IP can be optimally applied for minimally invasive surgery in breast cancer treatment, and a preliminary experience related to 15 patients and 20 sentinel nodes is reported here. We compared the results obtained with the IP to those obtained with an Anger camera and a traditional scintillation detector, and found them to be very promising. In particular the surgeon's work is greatly facilitated by direct visual guidance instead of a generic acoustic signal. PMID:12369557[PubMed - indexed for MEDLINE]

Intraoperative sentinel node detection by an innovative imaging probe / Campisi, C.; Soluri, A.; Stella, S.; Valenti, G.; Scopinaro, Francesco. - In: TUMORI. - ISSN 0300-8916. - STAMPA. - 88(3):(2002), pp. S56-58.

Intraoperative sentinel node detection by an innovative imaging probe.

SCOPINARO, Francesco
2002

Abstract

Intraoperative sentinel node detection by an innovative imaging probe. Campisi C, Soluri A, Stella S, Valenti G, Scopinaro F. SourceInstitute of Biomedical Technologies, National Research Council, Rome. campisi@itbm.rm.cnr.it Abstract Intraoperative tumor detection has been used in many applications, and today the sentinel node technique is a widely employed surgical procedure in breast cancer. Different detector systems are employed but several problems have been reported in clinical practice, in particular the difficulty to accurately detect the sentinel node within the axillary soft tissue. The problem is even greater for abdominal and thoracic tumors. We propose an innovative Imaging Probe (IP) able to visualize on a monitor the primary tumor and secondary lesions if appropriately radiolabeled. The IP can be optimally applied for minimally invasive surgery in breast cancer treatment, and a preliminary experience related to 15 patients and 20 sentinel nodes is reported here. We compared the results obtained with the IP to those obtained with an Anger camera and a traditional scintillation detector, and found them to be very promising. In particular the surgeon's work is greatly facilitated by direct visual guidance instead of a generic acoustic signal. PMID:12369557[PubMed - indexed for MEDLINE]
2002
01 Pubblicazione su rivista::01a Articolo in rivista
Intraoperative sentinel node detection by an innovative imaging probe / Campisi, C.; Soluri, A.; Stella, S.; Valenti, G.; Scopinaro, Francesco. - In: TUMORI. - ISSN 0300-8916. - STAMPA. - 88(3):(2002), pp. S56-58.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/87540
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact