A rapid, selective and effective method of extraction, clean-up and concentration of organophosphorous pesticides from wheat followed by electrospray (ESI) LC-MS/MS analysis was developed. The μ-SPE (micro-solid-phase extraction) procedure resulted in good analytical performance and reduced at the same time matrix effects, analysis time and solvent consumption. Limits of detection (LODs) and quantification (LOQs) were in the range of 0.3–10 and 1–30 μg kg−1, respectively, with good reproducibility (RSD ≤ 13.8) and recoveries between 75% and 109%. Coefficients of determination (r2) were greater than 0.996 for the studied pesticides. Despite the reduced sorbent bed mass of μ-SPE tips (4.2 mg), the analytical data showed that no saturation phenomena occurs in the tested range of concentration both for single compounds and mixtures. Several real samples were analysed and the concentrations of the selected pesticides were found to be below the respective maximum residue limit (MRLs). © 2016 The Author(s). Published by Taylor & Francis.
Micro-solid-phase extraction (µ-SPE) of organophosphorous pesticides from wheat followed by LC-MS/MS determination / Della Pelle, Flavio; Di Crescenzo, Maria Chiara; Sergi, Manuel; Montesano, Camilla; Di Ottavio, Francesca; Scarpone, Rossana; Scortichini, Giampiero; Compagnone, Dario. - In: FOOD ADDITIVES & CONTAMINANTS. PART A. CHEMISTRY, ANALYSIS, CONTROL, EXPOSURE & RISK ASSESSMENT. - ISSN 1944-0049. - ELETTRONICO. - 33:2(2016), pp. 291-299. [10.1080/19440049.2015.1123818]
Micro-solid-phase extraction (µ-SPE) of organophosphorous pesticides from wheat followed by LC-MS/MS determination
Sergi, Manuel;Montesano, Camilla;
2016
Abstract
A rapid, selective and effective method of extraction, clean-up and concentration of organophosphorous pesticides from wheat followed by electrospray (ESI) LC-MS/MS analysis was developed. The μ-SPE (micro-solid-phase extraction) procedure resulted in good analytical performance and reduced at the same time matrix effects, analysis time and solvent consumption. Limits of detection (LODs) and quantification (LOQs) were in the range of 0.3–10 and 1–30 μg kg−1, respectively, with good reproducibility (RSD ≤ 13.8) and recoveries between 75% and 109%. Coefficients of determination (r2) were greater than 0.996 for the studied pesticides. Despite the reduced sorbent bed mass of μ-SPE tips (4.2 mg), the analytical data showed that no saturation phenomena occurs in the tested range of concentration both for single compounds and mixtures. Several real samples were analysed and the concentrations of the selected pesticides were found to be below the respective maximum residue limit (MRLs). © 2016 The Author(s). Published by Taylor & Francis.File | Dimensione | Formato | |
---|---|---|---|
DellaPelle_Micro-solid-phase_2016.pdf
solo gestori archivio
Note: https://www.tandfonline.com/doi/full/10.1080/19440049.2015.1123818
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.67 MB
Formato
Adobe PDF
|
1.67 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.