Lighting very long road tunnels implies a high consumption of electrical energy since it requires a proper illumination during the whole day. In particular, in the daytime the illuminance levels right at the entrance and exit zones must be higher than those characterizing the inside of the tunnel, in this way the eye of the driver is able to adapt and be safe while passing from a high natural illumination of the outside to the lighting conditions characterizing the inside of the tunnel; consequently this causes a high energy demand. Therefore this case study investigates whether it is possible to minimize the energy demand through the exertion of an automatic new control system regulating the luminous fluxes of artificial sources (guaranteeing the parameters set by the regulation) with respect to the variation of the natural light characterizing the outside. The innovative control systems must be characterized by high reliability levels in order to guarantee conditions which are not dangerous to the driver if an outage occurs and minimize their maintenance costs. To carry out this type of study the software DIALux was used to simulate a tunnel with a dimming system (with lamps characterized by a high luminous efficiency) regulated by a pre-programmed logic control system (with high MTBF values). The savings obtained enabled the amortization of the solution here suggested in a time interval which makes it an advantageous choice economically speaking.
Management optimization of the luminous flux regulation of a lighting system in road tunnels / Salata, Ferdinando; Golasi, Iacopo; Poliziani, Alessandro; Futia, Antonio; DE LIETO VOLLARO, Emanuele; Coppi, Massimo; DE LIETO VOLLARO, Andrea. - ELETTRONICO. - 1:(2016), pp. 1-17. (Intervento presentato al convegno 16th CIRIAF National Congress Sustainable Development, Human Health and Environmental Protection tenutosi a Assisi, Italy nel April 7-9, 2016).
Management optimization of the luminous flux regulation of a lighting system in road tunnels
SALATA, FERDINANDO;GOLASI, IACOPO;DE LIETO VOLLARO, EMANUELE;COPPI, Massimo;DE LIETO VOLLARO, Andrea
2016
Abstract
Lighting very long road tunnels implies a high consumption of electrical energy since it requires a proper illumination during the whole day. In particular, in the daytime the illuminance levels right at the entrance and exit zones must be higher than those characterizing the inside of the tunnel, in this way the eye of the driver is able to adapt and be safe while passing from a high natural illumination of the outside to the lighting conditions characterizing the inside of the tunnel; consequently this causes a high energy demand. Therefore this case study investigates whether it is possible to minimize the energy demand through the exertion of an automatic new control system regulating the luminous fluxes of artificial sources (guaranteeing the parameters set by the regulation) with respect to the variation of the natural light characterizing the outside. The innovative control systems must be characterized by high reliability levels in order to guarantee conditions which are not dangerous to the driver if an outage occurs and minimize their maintenance costs. To carry out this type of study the software DIALux was used to simulate a tunnel with a dimming system (with lamps characterized by a high luminous efficiency) regulated by a pre-programmed logic control system (with high MTBF values). The savings obtained enabled the amortization of the solution here suggested in a time interval which makes it an advantageous choice economically speaking.File | Dimensione | Formato | |
---|---|---|---|
Salata_management_2016 .pdf
solo utenti autorizzati
Note: Articolo principale
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
1.55 MB
Formato
Adobe PDF
|
1.55 MB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.