BACKGROUND: Stent-graft migration is a late-term complication of endovas-cular abdominal aortic aneurysm repair (EVAR). A recent published study suggests that stent graft migration could be explained only by aortic neck elongation, mimicking the appearance of distal stent graft migration. Several studies about the use of dynamic CT Angiography (CTA) in the evaluation of aortic conformation changes during the cardiac cycle demonstrate that axial aortic pulsatility exists. No studies have been carried out to evaluate if a longitudinal aortic pulsatility also exists, that could justify the aortic neck elongation previously reported. AIM: To assess variations in length of proximal neck and infrarenal abdominal aorta in patients selected to undergo EVAR; to assess if longitudinal aortic pulsatility could modify EVAR planning. PATIENTS AND METHODS: 40 patients with Abdominal Aortic Aneurysm (AAA) underwent both static and dynamic ECG-gated 64-CTA (0.625 mm-slice-collimation; 1.25 mm-recon-struction increment). Manual measurements of aortic neck length and infrarenal abdominal aorta were performed on modified coronal images to determine dynamic conformational changes. RESULTS: Significant longitudinal pulsatility was demonstrated within aneurysm neck (19.1 ± 8.6%) and infrarenal abdominal aorta (6.6 ± 1.6%). When compared to dynamic measurements, the endograft previously selected according to static images in terms of fixation, would be potentially changed in 6/40 patients (15%) whereas 4/40 (10%) patients were not eligible for EVAR. CONCLUSIONS: Dynamic ECG-gated CTA may provide information regarding longitudinal pulsatile motion that could change the EVAR planning based on static imaging. Reported post-EVAR elongation of infrarenal aortic neck could be an unreal phenomenon only due to a conformational change during cardiac cycle.

Post-EVAR aortic neck elongation: Isareal phenomenon oraconformational change during the cardiac cycle? / Iezzi, R; Santoro, M.; Dattesi, R.; La Torre, M. F.; Guerra, A.; Antonuccio, E. G. M.; Rossi, Michele; Tinelli, G.; Snider, F.; Bonomo, L.. - In: EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES. - ISSN 1128-3602. - 18:7(2014), pp. 975-980.

Post-EVAR aortic neck elongation: Isareal phenomenon oraconformational change during the cardiac cycle?

ROSSI, Michele;
2014

Abstract

BACKGROUND: Stent-graft migration is a late-term complication of endovas-cular abdominal aortic aneurysm repair (EVAR). A recent published study suggests that stent graft migration could be explained only by aortic neck elongation, mimicking the appearance of distal stent graft migration. Several studies about the use of dynamic CT Angiography (CTA) in the evaluation of aortic conformation changes during the cardiac cycle demonstrate that axial aortic pulsatility exists. No studies have been carried out to evaluate if a longitudinal aortic pulsatility also exists, that could justify the aortic neck elongation previously reported. AIM: To assess variations in length of proximal neck and infrarenal abdominal aorta in patients selected to undergo EVAR; to assess if longitudinal aortic pulsatility could modify EVAR planning. PATIENTS AND METHODS: 40 patients with Abdominal Aortic Aneurysm (AAA) underwent both static and dynamic ECG-gated 64-CTA (0.625 mm-slice-collimation; 1.25 mm-recon-struction increment). Manual measurements of aortic neck length and infrarenal abdominal aorta were performed on modified coronal images to determine dynamic conformational changes. RESULTS: Significant longitudinal pulsatility was demonstrated within aneurysm neck (19.1 ± 8.6%) and infrarenal abdominal aorta (6.6 ± 1.6%). When compared to dynamic measurements, the endograft previously selected according to static images in terms of fixation, would be potentially changed in 6/40 patients (15%) whereas 4/40 (10%) patients were not eligible for EVAR. CONCLUSIONS: Dynamic ECG-gated CTA may provide information regarding longitudinal pulsatile motion that could change the EVAR planning based on static imaging. Reported post-EVAR elongation of infrarenal aortic neck could be an unreal phenomenon only due to a conformational change during cardiac cycle.
2014
Aortic neck elongation; Aortic Pulsatility; EVAR; Medicine (all); Pharmacology (medical)
01 Pubblicazione su rivista::01a Articolo in rivista
Post-EVAR aortic neck elongation: Isareal phenomenon oraconformational change during the cardiac cycle? / Iezzi, R; Santoro, M.; Dattesi, R.; La Torre, M. F.; Guerra, A.; Antonuccio, E. G. M.; Rossi, Michele; Tinelli, G.; Snider, F.; Bonomo, L.. - In: EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES. - ISSN 1128-3602. - 18:7(2014), pp. 975-980.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/865241
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact