The aim of our study was to compare the efficacy of the circular compression stapler and the circular mechanical stapler in transanal colorectal anastomosis after left colectomy or anterior rectal resection. We performed a retrospective analysis of 10 patients with disease of the, sigmoid colon or rectum (carcinoma or diverticular disease) who underwent left colectomy or anterior rectal resection with end-to-side transanal colorectal anastomosis. A follow-up was planned for all patients at 1, 3 and 6 months after surgery and the anastomosis was evaluated by colonoscopy at 1 year. In all patients an end-to-side transanal colorectal anastomosis was performed using a circular compression stapler (CCS group) or circular mechanical staplers with titanium staples (CMS group). The mean distance of the anastomosis from the anal margin was 6.4 ± 1.5 cm in the CCS group and 18.2 ± 11.2 cm in the CMS group. All patients in the CCS group expelled the ring after a mean time of 8.2 postoperative days. At 12 months colonoscopy revealed that all CCS patients had a satisfactory anastomosis with mean size of the colic lumen at the level of anastomotic line of 26.3 mm. In our experience the circular compression stapler a valuable alternative to the circular mechanical stapler for the creation of transanal colorectal anastomosis, in line with the relevant literature.

Use of the circular compression stapler and circular mechanical stapler in the end-to-side transanal colorectal anastomosis after left colon and rectal resections A single center experience / Pironi, Daniele; Vendettuoli, Maurizio; Pontone, Stefano; Panarese, Alessandra; Arcieri, Stefano; Filippini, Angelo; Grimaldi, Gianmarco. - In: ANNALI ITALIANI DI CHIRURGIA. - ISSN 2239-253X. - STAMPA. - 87:1(2016), pp. 23-30.

Use of the circular compression stapler and circular mechanical stapler in the end-to-side transanal colorectal anastomosis after left colon and rectal resections A single center experience

PIRONI, Daniele
;
VENDETTUOLI, MAURIZIO
Membro del Collaboration Group
;
PONTONE, Stefano
Membro del Collaboration Group
;
PANARESE, ALESSANDRA
Membro del Collaboration Group
;
ARCIERI, Stefano
Membro del Collaboration Group
;
FILIPPINI, Angelo
Membro del Collaboration Group
;
GRIMALDI, GIANMARCO
Conceptualization
2016

Abstract

The aim of our study was to compare the efficacy of the circular compression stapler and the circular mechanical stapler in transanal colorectal anastomosis after left colectomy or anterior rectal resection. We performed a retrospective analysis of 10 patients with disease of the, sigmoid colon or rectum (carcinoma or diverticular disease) who underwent left colectomy or anterior rectal resection with end-to-side transanal colorectal anastomosis. A follow-up was planned for all patients at 1, 3 and 6 months after surgery and the anastomosis was evaluated by colonoscopy at 1 year. In all patients an end-to-side transanal colorectal anastomosis was performed using a circular compression stapler (CCS group) or circular mechanical staplers with titanium staples (CMS group). The mean distance of the anastomosis from the anal margin was 6.4 ± 1.5 cm in the CCS group and 18.2 ± 11.2 cm in the CMS group. All patients in the CCS group expelled the ring after a mean time of 8.2 postoperative days. At 12 months colonoscopy revealed that all CCS patients had a satisfactory anastomosis with mean size of the colic lumen at the level of anastomotic line of 26.3 mm. In our experience the circular compression stapler a valuable alternative to the circular mechanical stapler for the creation of transanal colorectal anastomosis, in line with the relevant literature.
2016
Anastomotic leakage, Anastomotic stenosis, Circular compression stapler, Circular mechanical stapler, Transanal colorectal anastomosis.
01 Pubblicazione su rivista::01a Articolo in rivista
Use of the circular compression stapler and circular mechanical stapler in the end-to-side transanal colorectal anastomosis after left colon and rectal resections A single center experience / Pironi, Daniele; Vendettuoli, Maurizio; Pontone, Stefano; Panarese, Alessandra; Arcieri, Stefano; Filippini, Angelo; Grimaldi, Gianmarco. - In: ANNALI ITALIANI DI CHIRURGIA. - ISSN 2239-253X. - STAMPA. - 87:1(2016), pp. 23-30.
File allegati a questo prodotto
File Dimensione Formato  
Pironi_Circular-stapler_2016.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.93 MB
Formato Adobe PDF
1.93 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/863493
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact