Studies have analyzed three-dimensional complex motion of the shoulder in healthy subjects or patients undergoing total shoulder arthroplasty (TSA) or reverse shoulder arthroplasty (RSA). No study to date has assessed the reaching movements in patients with TSA or RSA. Twelve patients with TSA (Group A) and 12 with RSA (Group B) underwent kinematic analysis of reaching movements directed at four targets. The results were compared to those of 12 healthy subjects (Group C). The assessed parameters were hand-to-target distance, target-approaching velocity, humeral-elevation angular velocity, normalized jerk (indicating motion fluidity), elbow extension and humeral elevation angles. Mean Constant score increased by 38 points in Group A and 47 in Group B after surgery. In three of the tasks, there were no significant differences between healthy subjects and patients in the study groups. Mean target-approaching velocity and humeral-elevation angular velocity were significantly greater in the control group than in study groups and, overall, greater in Group A than Group B. Movement fluidity was significantly greater in the controls, with patients in Group B showing greater fluidity than those in Group A. Reaching movements in the study groups were comparable, in three of the tasks, to those in the control group. However, the latter performed significantly better with regard to target-approaching velocity, humeral-elevation angular velocity and movement fluidity, which are the most representative characteristics of reaching motion. These differences, that may be related to deterioration of shoulder proprioception after prosthetic implant, might possibly be decreased with appropriate rehabilitation.
Kinematic analysis of reaching movements of the upper limb after total or reverse shoulder arthroplasty / Postacchini, Roberto; Paoloni, Marco; Carbone, Stefano; Fini, Massimo; Santilli, Valter; Postacchini, Franco; Mangone, Massimiliano. - In: JOURNAL OF BIOMECHANICS. - ISSN 0021-9290. - STAMPA. - 48:12(2015), pp. 3192-3198. [10.1016/j.jbiomech.2015.07.002]
Kinematic analysis of reaching movements of the upper limb after total or reverse shoulder arthroplasty
PAOLONI, Marco;CARBONE, STEFANO;SANTILLI, VALTER;POSTACCHINI, Franco;MANGONE, MASSIMILIANO
2015
Abstract
Studies have analyzed three-dimensional complex motion of the shoulder in healthy subjects or patients undergoing total shoulder arthroplasty (TSA) or reverse shoulder arthroplasty (RSA). No study to date has assessed the reaching movements in patients with TSA or RSA. Twelve patients with TSA (Group A) and 12 with RSA (Group B) underwent kinematic analysis of reaching movements directed at four targets. The results were compared to those of 12 healthy subjects (Group C). The assessed parameters were hand-to-target distance, target-approaching velocity, humeral-elevation angular velocity, normalized jerk (indicating motion fluidity), elbow extension and humeral elevation angles. Mean Constant score increased by 38 points in Group A and 47 in Group B after surgery. In three of the tasks, there were no significant differences between healthy subjects and patients in the study groups. Mean target-approaching velocity and humeral-elevation angular velocity were significantly greater in the control group than in study groups and, overall, greater in Group A than Group B. Movement fluidity was significantly greater in the controls, with patients in Group B showing greater fluidity than those in Group A. Reaching movements in the study groups were comparable, in three of the tasks, to those in the control group. However, the latter performed significantly better with regard to target-approaching velocity, humeral-elevation angular velocity and movement fluidity, which are the most representative characteristics of reaching motion. These differences, that may be related to deterioration of shoulder proprioception after prosthetic implant, might possibly be decreased with appropriate rehabilitation.File | Dimensione | Formato | |
---|---|---|---|
Postacchini_preprint_Kinematic_2015.pdf
accesso aperto
Tipologia:
Documento in Pre-print (manoscritto inviato all'editore, precedente alla peer review)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
754.63 kB
Formato
Adobe PDF
|
754.63 kB | Adobe PDF | |
Postacchini_Kinematic_2015.pdf
solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza:
Tutti i diritti riservati (All rights reserved)
Dimensione
521.24 kB
Formato
Adobe PDF
|
521.24 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.