Several studies have reported that patients (pts) with severe aortic stenosis and similar pressure gradients or even similar aortic valve areas may have quite different symptomatic status and clinical outcomes suggesting that other factors might have a significant impact on the pathophysiology of this disease. Our purpose was to assess the severity of subendocardial wall dysfunction in symptomatic and asymptomatic pts with aortic stenosis using tissue Doppler imaging (TDI), strain rate imaging (SRI) and cyclic variation of integrated backscatter (IB). We studied 68 pts with aortic valvar stenosis and 46 subjects with no signs of heart disease. SRI/IB indexes were calculated in the apical four chambers views at endocardial level. Early diastolic endocardial strain rate showed the best correlation with transvalvar pressure gradients and valve areas. Compared with controls, symptomatic pts showed a more marked decrease in endocardial strain, strain rate and cyclic variation of IB. Receiver operating characteristic (ROC) curves suggested that the thresholds offering an adequate compromise between sensitivity and specificity for the prediction of symptoms were >/=60 mm Hg for the pressure gradient, less than 0.60 cm(2)/m(2) for aortic valve area, less than 20% for strain, less than 2.0 s(-1) for strain rate and less than 3.0 dB for cyclic variation. The combination of pressure gradient, aortic valve area and SRI/IB parameters resulted in an improvement of the overall performance for predicting the symptomatic state. Thus, SRI/IB parameters have an incremental value in differentiating symptomatic and asymptomatic pts with aortic stenosis compared with conventional hemodynamic parameters.

Assessment of severity in aortic stenosis – Incremental value of endocardial function parameters compared to standard indexes / Vitarelli, Antonino; CORTES MORICHETTI, M; Conde, Y; Cimino, E; D'Orazio, Simona; Stellato, Simona; Padella, V; Caranci, Fiorella; Battaglia, Daniela. - In: ULTRASOUND IN MEDICINE AND BIOLOGY. - ISSN 0301-5629. - STAMPA. - 33 (8):(2007), pp. 1224-1235. [10.1016/j.ultrasmedbio.2007.02.008]

Assessment of severity in aortic stenosis – Incremental value of endocardial function parameters compared to standard indexes

VITARELLI, Antonino;D'ORAZIO, SIMONA;STELLATO, SIMONA;CARANCI, FIORELLA;BATTAGLIA, DANIELA
2007

Abstract

Several studies have reported that patients (pts) with severe aortic stenosis and similar pressure gradients or even similar aortic valve areas may have quite different symptomatic status and clinical outcomes suggesting that other factors might have a significant impact on the pathophysiology of this disease. Our purpose was to assess the severity of subendocardial wall dysfunction in symptomatic and asymptomatic pts with aortic stenosis using tissue Doppler imaging (TDI), strain rate imaging (SRI) and cyclic variation of integrated backscatter (IB). We studied 68 pts with aortic valvar stenosis and 46 subjects with no signs of heart disease. SRI/IB indexes were calculated in the apical four chambers views at endocardial level. Early diastolic endocardial strain rate showed the best correlation with transvalvar pressure gradients and valve areas. Compared with controls, symptomatic pts showed a more marked decrease in endocardial strain, strain rate and cyclic variation of IB. Receiver operating characteristic (ROC) curves suggested that the thresholds offering an adequate compromise between sensitivity and specificity for the prediction of symptoms were >/=60 mm Hg for the pressure gradient, less than 0.60 cm(2)/m(2) for aortic valve area, less than 20% for strain, less than 2.0 s(-1) for strain rate and less than 3.0 dB for cyclic variation. The combination of pressure gradient, aortic valve area and SRI/IB parameters resulted in an improvement of the overall performance for predicting the symptomatic state. Thus, SRI/IB parameters have an incremental value in differentiating symptomatic and asymptomatic pts with aortic stenosis compared with conventional hemodynamic parameters.
2007
Echocardiography; Tissue Doppler imaging; Strain rate imaging; Strain imaging; Integrated backscatter; Subendocardial dysfunction; Aortic stenosis
01 Pubblicazione su rivista::01a Articolo in rivista
Assessment of severity in aortic stenosis – Incremental value of endocardial function parameters compared to standard indexes / Vitarelli, Antonino; CORTES MORICHETTI, M; Conde, Y; Cimino, E; D'Orazio, Simona; Stellato, Simona; Padella, V; Caranci, Fiorella; Battaglia, Daniela. - In: ULTRASOUND IN MEDICINE AND BIOLOGY. - ISSN 0301-5629. - STAMPA. - 33 (8):(2007), pp. 1224-1235. [10.1016/j.ultrasmedbio.2007.02.008]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/84863
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact