This review aims to provide a synthesis of the published evidence regarding the rationale and clinical benefits of cardiac resynchronization therapy (CRT) with implantable atrial-synchronized biventricular pacing (BVP) devices in patients with moderate to advanced heart failure and intra- and interventricular conduction delays. In addition, it addresses clinical and technical issues that have yet to be resolved, such as the selection of the most suitable candidates for CRT; the usefulness of combining BVP with automatic defibrillation backup; the value of CRT in patients with atrial fibrillation; the importance of alternative sites of pacing, such as the atrial septum and the right ventricular (RV) outflow tract; the harmful effects of the long-standing practice of producing an iatrogenic left bundle branch block by conventional RV pacing in patients receiving standard permanent pacemakers; the question of precisely where on the left ventricle optimal pacing is achieved; and the potential applications of CRT in patients with pediatric or congenital heart disease. Considering how major advances have been achieved since the first clinical application of CRT in 1994, one can be optimistic about the future of the electrotherapeutic management of heart failure. (c) 2005 Elsevier Inc. All rights reserved.

Benefits, unresolved questions, and technical issues of cardiac resynchronization therapy for heart failure / Salvatore, Rosanio; Ahmad M., Schwarz Er; Praveen, Jammula; Vitarelli, Antonino; Barry F., Uretsky; Yochai, Birnbaum; David L., Ware; Shaul, Atar; Mohammad, Saeed. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - STAMPA. - 96:5(2005), pp. 710-717. [10.1016/j.amjcard.2005.04.050]

Benefits, unresolved questions, and technical issues of cardiac resynchronization therapy for heart failure

VITARELLI, Antonino;
2005

Abstract

This review aims to provide a synthesis of the published evidence regarding the rationale and clinical benefits of cardiac resynchronization therapy (CRT) with implantable atrial-synchronized biventricular pacing (BVP) devices in patients with moderate to advanced heart failure and intra- and interventricular conduction delays. In addition, it addresses clinical and technical issues that have yet to be resolved, such as the selection of the most suitable candidates for CRT; the usefulness of combining BVP with automatic defibrillation backup; the value of CRT in patients with atrial fibrillation; the importance of alternative sites of pacing, such as the atrial septum and the right ventricular (RV) outflow tract; the harmful effects of the long-standing practice of producing an iatrogenic left bundle branch block by conventional RV pacing in patients receiving standard permanent pacemakers; the question of precisely where on the left ventricle optimal pacing is achieved; and the potential applications of CRT in patients with pediatric or congenital heart disease. Considering how major advances have been achieved since the first clinical application of CRT in 1994, one can be optimistic about the future of the electrotherapeutic management of heart failure. (c) 2005 Elsevier Inc. All rights reserved.
2005
biventricular pacing; candidates for resynchronization therapy; cardiac resynchronization therapy; heart failure
01 Pubblicazione su rivista::01a Articolo in rivista
Benefits, unresolved questions, and technical issues of cardiac resynchronization therapy for heart failure / Salvatore, Rosanio; Ahmad M., Schwarz Er; Praveen, Jammula; Vitarelli, Antonino; Barry F., Uretsky; Yochai, Birnbaum; David L., Ware; Shaul, Atar; Mohammad, Saeed. - In: THE AMERICAN JOURNAL OF CARDIOLOGY. - ISSN 0002-9149. - STAMPA. - 96:5(2005), pp. 710-717. [10.1016/j.amjcard.2005.04.050]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/84856
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 17
social impact