Legionella spp. is considered an emerging microorganism involved in aquatic environments contamination and cause of Legionnaires' disease. The aims of the study are to evaluate the level of contamination of Legionella spp. in the water system of the largest Hospital of Apulia region during a 4-year surveillance and to establish, by molecular method, the presence of a predominant genotype of L. pn. sg 1. The results showed that Legionella spp. was present in 36% of water samples with Legionella pneumophila serogroup 1 (L. pn. sg 1) the most prevalent species and serogroup and the wards most contaminated are the high risk units. In addition, despite four main clones of L. pn. sg 1 were identified, a predominant genotype existed. In conclusion the study demonstrates the necessity for periodic evaluation on hospitals water system to assess the potential contamination of Legionella spp., performing decontamination in the presence of bacterial contamination, even low, in particular in high risk wards. Moreover, the switching of the disinfection methods may be suggested in order to prevent resistance phenomenon by some L. pn. sg 1 clones.

Environmental surveillance and molecular investigation of Legionella spp. in Apulia, in the years 2008-2011 / Iatta, R; Cuna, T; Napoli, Christian; De Giglio, O; Montagna, M. T.. - In: ANNALI DI IGIENE MEDICINA PREVENTIVA E DI COMUNITÀ. - ISSN 1120-9135. - 25:5(2013), p. 435-41.

Environmental surveillance and molecular investigation of Legionella spp. in Apulia, in the years 2008-2011

NAPOLI, CHRISTIAN;
2013

Abstract

Legionella spp. is considered an emerging microorganism involved in aquatic environments contamination and cause of Legionnaires' disease. The aims of the study are to evaluate the level of contamination of Legionella spp. in the water system of the largest Hospital of Apulia region during a 4-year surveillance and to establish, by molecular method, the presence of a predominant genotype of L. pn. sg 1. The results showed that Legionella spp. was present in 36% of water samples with Legionella pneumophila serogroup 1 (L. pn. sg 1) the most prevalent species and serogroup and the wards most contaminated are the high risk units. In addition, despite four main clones of L. pn. sg 1 were identified, a predominant genotype existed. In conclusion the study demonstrates the necessity for periodic evaluation on hospitals water system to assess the potential contamination of Legionella spp., performing decontamination in the presence of bacterial contamination, even low, in particular in high risk wards. Moreover, the switching of the disinfection methods may be suggested in order to prevent resistance phenomenon by some L. pn. sg 1 clones.
2013
Agglutination Tests; Bacterial Load; Cross Infection; DNA, Bacterial; Disinfection; Genotype; Hospital Design and Construction; Humans; Italy; Legionella; Legionellosis; Patients' Rooms; Phylogeny; Retrospective Studies; Sanitary Engineering; Serotyping; Water Purification; Environmental Monitoring; Water Microbiology; Water Pollution; Water Supply
01 Pubblicazione su rivista::01a Articolo in rivista
Environmental surveillance and molecular investigation of Legionella spp. in Apulia, in the years 2008-2011 / Iatta, R; Cuna, T; Napoli, Christian; De Giglio, O; Montagna, M. T.. - In: ANNALI DI IGIENE MEDICINA PREVENTIVA E DI COMUNITÀ. - ISSN 1120-9135. - 25:5(2013), p. 435-41.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/833413
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact