OBJECTIVE: To evaluate the ability of colour Doppler transoesophageal echocardiography (TOE) to assess quantitatively prosthetic mitral valve insufficiency. METHODS: 47 patients were studied with multiplane TOE and cardiac catheterisation. Proximal jet diameter was measured as the largest diameter of the vena contracta. Regurgitant area was measured by planimetry of the largest turbulent jet during systole. Flow convergence zone was considered to be present when a localised area of increased systolic velocities was apparent on the left ventricular side of the valve prosthesis. Pulmonary vein flow velocity was measured at peak systole and diastole. RESULTS: Mean (SD) proximal jet diameter was 0.63 (0.16) cm, with good correlation with angiographic grades (r = 0.83). Mean (SD) maximum colour jet area was 7.9 (2.5) cm2 (r = 0.69) with worse correlation if a single imaging plane was used for measurements (r = 0.62). The ratio of systolic to diastolic peak pulmonary flow velocity averaged 0.7 (1.3) cm (r = -0.66) with better correlation (r = -0.71) if patients with atrial fibrillation were excluded. Mean (SD) regurgitant flow rate was 168 (135) ml/s and regurgitant orifice area was 0.56 (0.43) cm2, with good correlation with angiography (r = 0.77 and r = 0.78, respectively). CONCLUSIONS: TOE correctly identified angiographically severe prosthetic mitral regurgitation, mainly by the assessment of the flow convergence region and the proximal diameter of the regurgitant jet.

Assessment of severity of mechanical prosthetic mitral valve regurgitation by transoesophageal echocardiography / Vitarelli, Antonino; Conde, Y; Cimino, E; Leone, T; D'Angeli, I; D'Orazio, S; Stellato, S.. - In: HEART. - ISSN 1355-6037. - STAMPA. - 90:(2004), pp. 539-544. [10.1136/hrt.2003.026823]

Assessment of severity of mechanical prosthetic mitral valve regurgitation by transoesophageal echocardiography

VITARELLI, Antonino;
2004

Abstract

OBJECTIVE: To evaluate the ability of colour Doppler transoesophageal echocardiography (TOE) to assess quantitatively prosthetic mitral valve insufficiency. METHODS: 47 patients were studied with multiplane TOE and cardiac catheterisation. Proximal jet diameter was measured as the largest diameter of the vena contracta. Regurgitant area was measured by planimetry of the largest turbulent jet during systole. Flow convergence zone was considered to be present when a localised area of increased systolic velocities was apparent on the left ventricular side of the valve prosthesis. Pulmonary vein flow velocity was measured at peak systole and diastole. RESULTS: Mean (SD) proximal jet diameter was 0.63 (0.16) cm, with good correlation with angiographic grades (r = 0.83). Mean (SD) maximum colour jet area was 7.9 (2.5) cm2 (r = 0.69) with worse correlation if a single imaging plane was used for measurements (r = 0.62). The ratio of systolic to diastolic peak pulmonary flow velocity averaged 0.7 (1.3) cm (r = -0.66) with better correlation (r = -0.71) if patients with atrial fibrillation were excluded. Mean (SD) regurgitant flow rate was 168 (135) ml/s and regurgitant orifice area was 0.56 (0.43) cm2, with good correlation with angiography (r = 0.77 and r = 0.78, respectively). CONCLUSIONS: TOE correctly identified angiographically severe prosthetic mitral regurgitation, mainly by the assessment of the flow convergence region and the proximal diameter of the regurgitant jet.
2004
prosthetic mitral valve; transoesophageal echocardiography; cardiac catheterisation
01 Pubblicazione su rivista::01a Articolo in rivista
Assessment of severity of mechanical prosthetic mitral valve regurgitation by transoesophageal echocardiography / Vitarelli, Antonino; Conde, Y; Cimino, E; Leone, T; D'Angeli, I; D'Orazio, S; Stellato, S.. - In: HEART. - ISSN 1355-6037. - STAMPA. - 90:(2004), pp. 539-544. [10.1136/hrt.2003.026823]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/82468
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 23
social impact