Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
Catalogo dei prodotti della ricerca
Virgo is a laser Michelson interferometer with 3-km long Fabry-Perot in the arms, aiming at the detection of gravitational waves emitted by astrophysical sources in the frequency band from 10 Hz to few kHz. The core of the detector, the central interferometer, was installed first. It is a recycled Michelson interferometer, with 6-m long arms, obtained by replacing the 3-km long Fabry-Perot cavities with high reflectivity mirrors and using the same components designed for Virgo. In particular all the mirrors of the interferometer are suspended from the seismic isolators that represent the main unique characteristic of the Virgo detector. The interferometer has been controlled by means of a fully digital control system, capable of monitoring and controlling the relative position of the mirrors with an accuracy of 10(-12) m. The best displacement sensitivity was 10(-13) m/rootHz at 10 Hz and 8 X 10(-17) m/rootHz above 1 kHz. This article describes the detector configuration, the tests performed in view of commissioning the full detector and the main results obtained. (C) 2003 Published by Elsevier B.V.
The commissioning of the central interferometer of the Virgo gravitational wave detector / Acernese, F.; Amico, P.; Alshourbagy, M.; Antonucci, F.; Aoudia, S.; Astone, P.; Avino, S.; Babusci, D.; Ballardin, G.; Barone, F.; Barsotti, L.; Barsuglia, M.; Beauville, F.; Bigotta, S.; Birindelli, S.; Bizouard, M. A.; Boccara, C.; Bondu, F.; Bosi, L.; Bradaschia, C.; Braccini, S.; Brillet, A.; Brisson, V.; Buskulic, D.; Calloni, E.; Campagna, E.; Carbognani, F.; Cavalier, F.; Cavalieri, R.; Cella, G.; Cesarini, E.; Chassande Mottin, E.; Christensen, N.; Corda, C.; Corsi, A.; Cottone, F.; Clapson, A. C.; Cleva, F.; Coulon, J. P.; Cuoco, E.; Dari, A.; Dattilo, V.; Davier, M.; Del Prete, M.; De Rosa, R.; Di Fiore, L.; Di Virgilio, A.; Dujardin, B.; Eleuteri, A.; Ferrante, I.; Fidecaro, F.; Fiori, I.; Flaminio, R.; Fournier, J. D.; Frasca, Sergio; Frasconi, F.; Gammaitoni, L.; Garufi, F.; Genin, E.; Gennai, A.; Giazotto, A.; Giordano, G.; Giordano, L.; Gouaty, R.; Grosjean, D.; Guidi, G.; Hebri, S.; Heitmann, H.; Hello, P.; Karkar, S.; Kreckelbergh, S.; La Penna, P.; Laval, M.; Leroy, N.; Letendre, N.; Lopez, B.; Lorenzini, M.; Loriette, V.; Losurdo, G.; Mackowski, J. M.; Majorana, E.; Man, C. N.; Mantovani, M.; Marchesoni, F.; Marion, F.; Marque, J.; Martelli, F.; Masserot, A.; Mazzoni, M.; Milano, L.; Menzinger, F.; Moins, C.; Moreau, J.; Morgado, N.; Mours, B.; Nocera, F.; Palomba, C.; Paoletti, F.; Pardi, S.; Pasqualetti, A.; Passaquieti, R.; Passuello, D.; Piergiovanni, F.; Pinard, L.; Poggiani, R.; Punturo, M.; Puppo, P.; Qipiani, K.; Rapagnani, Piero; Reita, V.; Remillieux, A.; Ricci, Fulvio; Ricciardi, I.; Ruggi, P.; Russo, G.; Solimeno, S.; Spallicci, A.; Tarallo, M.; Tonelli, M.; Toncelli, A.; Tournefier, E.; Travasso, F.; Tremola, C.; Gabriele, Vajente; Verkindt, D.; Vetrano, F.; Vicere, A.; Vinet, J. Y.; Vocca, H.; Yvert, M.. - In: ASTROPARTICLE PHYSICS. - ISSN 0927-6505. - 21:1(2004), pp. 1-22. [10.1016/j.astropartphys.2003.12.004]
The commissioning of the central interferometer of the Virgo gravitational wave detector
Virgo is a laser Michelson interferometer with 3-km long Fabry-Perot in the arms, aiming at the detection of gravitational waves emitted by astrophysical sources in the frequency band from 10 Hz to few kHz. The core of the detector, the central interferometer, was installed first. It is a recycled Michelson interferometer, with 6-m long arms, obtained by replacing the 3-km long Fabry-Perot cavities with high reflectivity mirrors and using the same components designed for Virgo. In particular all the mirrors of the interferometer are suspended from the seismic isolators that represent the main unique characteristic of the Virgo detector. The interferometer has been controlled by means of a fully digital control system, capable of monitoring and controlling the relative position of the mirrors with an accuracy of 10(-12) m. The best displacement sensitivity was 10(-13) m/rootHz at 10 Hz and 8 X 10(-17) m/rootHz above 1 kHz. This article describes the detector configuration, the tests performed in view of commissioning the full detector and the main results obtained. (C) 2003 Published by Elsevier B.V.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/81733
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
31
24
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.