We describe the design and fabrication of biochips based on 1-D photonic crystals supporting Bloch surface waves for label-free optical biosensing. The optical properties of Bloch surface waves are studied in relation to the geometry of the photonic crystals and on the properties of the dielectric materials used for the fabrication. The planar stacks of the biochips are composed of silica, tantala, and titania that were deposited using plasma-ion-assisted evaporation under high-vacuum conditions. The biochip surfaces were functionalized by silanization, and appropriate fluidic cells were designed to operate in an automated platform. An angularly resolved ellipsometric optical sensing apparatus was assembled to carry out the sensing studies. The angular operation is obtained by a focused laser beam at a fixed wavelength and detection of the angular reflectance spectrum by means of an array detector. The results of the experimental characterization of the physical properties of the fabricated biochips show that their characteristics, in terms of sensitivity and figure of merit, match those expected from the numerical simulations. Practical application of the sensor was demonstrated by detecting a specific glycoprotein, Angio-poietin 2, that is involved in angiogenesis and inflammation processes. The protocol used for the label-free detection of Angiopoietin 2 is described, and the results of an exemplary assay, carried out at a relatively high concentration of 1 μg/ml, are given and confirm that an efficient detection can be achieved. The limit of detection of the biochips for Angiopoietin 2, based on the protocol used, is 1.5 pg/mm2 in buffer solution. The efficiency of the label-free assay is confirmed by independent measurements carried out by means of confocal fluorescence microscopy.
Label-Free detection of tumor angiogenesis biomarker angiopoietin 2 using bloch surface waves on one dimensional photonic crystals / Sinibaldi, Alberto; Danz, Norbert; Anopchenko, Oleksiy; Munzert, Peter; Schmieder, Stefan; Chandrawati, Rona; Rizzo, Riccardo; Rana, Subinoy; Sonntag, Frank; Occhicone, Agostino; Napione, Lucia; De Panfilis, Simone; Stevens, Molly M.; Michelotti, Francesco. - In: JOURNAL OF LIGHTWAVE TECHNOLOGY. - ISSN 0733-8724. - STAMPA. - 33:16(2015), pp. 3385-3393. [10.1109/JLT.2015.2448795]
Label-Free detection of tumor angiogenesis biomarker angiopoietin 2 using bloch surface waves on one dimensional photonic crystals
SINIBALDI, ALBERTO;ANOPCHENKO, OLEKSIY;RIZZO, Riccardo;OCCHICONE, AGOSTINO;MICHELOTTI, Francesco
2015
Abstract
We describe the design and fabrication of biochips based on 1-D photonic crystals supporting Bloch surface waves for label-free optical biosensing. The optical properties of Bloch surface waves are studied in relation to the geometry of the photonic crystals and on the properties of the dielectric materials used for the fabrication. The planar stacks of the biochips are composed of silica, tantala, and titania that were deposited using plasma-ion-assisted evaporation under high-vacuum conditions. The biochip surfaces were functionalized by silanization, and appropriate fluidic cells were designed to operate in an automated platform. An angularly resolved ellipsometric optical sensing apparatus was assembled to carry out the sensing studies. The angular operation is obtained by a focused laser beam at a fixed wavelength and detection of the angular reflectance spectrum by means of an array detector. The results of the experimental characterization of the physical properties of the fabricated biochips show that their characteristics, in terms of sensitivity and figure of merit, match those expected from the numerical simulations. Practical application of the sensor was demonstrated by detecting a specific glycoprotein, Angio-poietin 2, that is involved in angiogenesis and inflammation processes. The protocol used for the label-free detection of Angiopoietin 2 is described, and the results of an exemplary assay, carried out at a relatively high concentration of 1 μg/ml, are given and confirm that an efficient detection can be achieved. The limit of detection of the biochips for Angiopoietin 2, based on the protocol used, is 1.5 pg/mm2 in buffer solution. The efficiency of the label-free assay is confirmed by independent measurements carried out by means of confocal fluorescence microscopy.File | Dimensione | Formato | |
---|---|---|---|
JLWT_BILOBA_ang2 assay_Revised_for IRIS.pdf
solo gestori archivio
Tipologia:
Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza:
Creative commons
Dimensione
916.79 kB
Formato
Adobe PDF
|
916.79 kB | Adobe PDF | Contatta l'autore |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.