An imaging system based on the Medipix2, a single photon counting pixel readout ASIC for X-ray hybrid detectors, has been developed for tomography imaging applications. The "quad assembly" houses four Medipix2 chips placed in a 2 x 2 array with an active area of about 3 x 3 cm(2). The readout system we present consists of four electronic cards and exploits the Medipix2 parallel readout mode and a fast optical link based on the Glink standard, giving high flexibility and EM interference immunity over long distance connections. A PCI board interfaces the imaging system to a standard PC. We expect a frame rate of 25 frame/s which allows real-time X-ray imaging acquisitions and fast computed tomography (CT) scanning. In this paper, we describe the DAQ project and the status of development. (c) 2007 Elsevier B.V. All rights reserved.

Optical link based readout system for Medipix2 quad X-ray detector / V., Fanti; R., Marzeddu; P., Randaccio; A., Aloisio; A., Del Guerra; N., Lanconelli; G., Mettivier; M. C., Montesi; Pani, Roberto; P., Russo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 576:1(2007), pp. 137-141. (Intervento presentato al convegno 8th International Workshop on Radiation Imaging Detectors tenutosi a Pisa, ITALY nel JUL 02-06, 2006) [10.1016/j.nima.2007.01.141].

Optical link based readout system for Medipix2 quad X-ray detector

PANI, Roberto;
2007

Abstract

An imaging system based on the Medipix2, a single photon counting pixel readout ASIC for X-ray hybrid detectors, has been developed for tomography imaging applications. The "quad assembly" houses four Medipix2 chips placed in a 2 x 2 array with an active area of about 3 x 3 cm(2). The readout system we present consists of four electronic cards and exploits the Medipix2 parallel readout mode and a fast optical link based on the Glink standard, giving high flexibility and EM interference immunity over long distance connections. A PCI board interfaces the imaging system to a standard PC. We expect a frame rate of 25 frame/s which allows real-time X-ray imaging acquisitions and fast computed tomography (CT) scanning. In this paper, we describe the DAQ project and the status of development. (c) 2007 Elsevier B.V. All rights reserved.
2007
data acquisition; optical link; pci interface; x-ray imaging
01 Pubblicazione su rivista::01a Articolo in rivista
Optical link based readout system for Medipix2 quad X-ray detector / V., Fanti; R., Marzeddu; P., Randaccio; A., Aloisio; A., Del Guerra; N., Lanconelli; G., Mettivier; M. C., Montesi; Pani, Roberto; P., Russo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 576:1(2007), pp. 137-141. (Intervento presentato al convegno 8th International Workshop on Radiation Imaging Detectors tenutosi a Pisa, ITALY nel JUL 02-06, 2006) [10.1016/j.nima.2007.01.141].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/81283
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact