We present a study of the beam coupling impedance due to trapped modes of a new protection septum that will be installed in the CERN Proton Synchrotron (PS) during the Long Shutdown 1 (LS1). The interaction between the particle field and the discontinuities inside the septum generates electromagnetic fields localized in a particular region inside the device. These resonances, producing narrow peaks in the coupling impedance, can be potential source of beam instabilities for high intensity particle accelerators like PS. The final outcome of these studies is the basis for the acceptance of the septum installation in section 15 of the PS ring.

Beam coupling impedance simulation and RF measurements of a passive extraction septum for particle absorbing in the CERN Proton Synchrotron / Migliorati, Mauro; Persichelli, Serena. - (2014), pp. 245-248. (Intervento presentato al convegno XX Riunione Nazionale di Elettromagnetismo tenutosi a Padova nel 15-18 settembre 2014).

Beam coupling impedance simulation and RF measurements of a passive extraction septum for particle absorbing in the CERN Proton Synchrotron

MIGLIORATI, Mauro;PERSICHELLI, SERENA
2014

Abstract

We present a study of the beam coupling impedance due to trapped modes of a new protection septum that will be installed in the CERN Proton Synchrotron (PS) during the Long Shutdown 1 (LS1). The interaction between the particle field and the discontinuities inside the septum generates electromagnetic fields localized in a particular region inside the device. These resonances, producing narrow peaks in the coupling impedance, can be potential source of beam instabilities for high intensity particle accelerators like PS. The final outcome of these studies is the basis for the acceptance of the septum installation in section 15 of the PS ring.
2014
XX Riunione Nazionale di Elettromagnetismo
Beam coupling impedances, RF measurements, trapped modes.
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Beam coupling impedance simulation and RF measurements of a passive extraction septum for particle absorbing in the CERN Proton Synchrotron / Migliorati, Mauro; Persichelli, Serena. - (2014), pp. 245-248. (Intervento presentato al convegno XX Riunione Nazionale di Elettromagnetismo tenutosi a Padova nel 15-18 settembre 2014).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/810482
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact