The paper shows the results obtained by measuring the variation in the risk indi-cators when the fire in tunnel induces railway accident. According to the principle of safety performance effectiveness, the analysis of reliability, availability and rele-vance of subsystems making up the tunnel system, was based on quantitative risk analysis (QRA) and approach RAMS. By modifying the design of safety power sys-tem, comparative evaluations on the risk level were conducted in order to obtaining useful results to the effectiveness of the emergency management in the tunnel in case of fire. The architecture of wiring system shows already high levels of reliabil-ity to protection from simple faults; substantial rooms for improvement are avail-able based on the power of lighting and on the fire resistance.

Il lavoro propone i risultati ottenuti da una valutazione di elasticità del rischio in caso di incidente ferroviario in galleria e di incendio in particolare. Le verifiche di affidabilità, di disponibilità e di rilevanza dei sottosistemi costituenti il sistema gal-leria, condotte mediante analisi di rischio quantitativa (QRA) e approccio RAMS, sono sviluppate nel rispetto del principio di effettività delle prestazioni di sicurezza. Nel dettaglio sono state condotte valutazioni comparative sul rischio al variare del design dei cablaggi di forza motrice di impianti di sicurezza, ottenendo risultati utili a migliorare la gestione dell’emergenza in galleria in caso di incendio. Lo studio condotto ha evidenziato che mentre l’architettura tipo del cablaggio presenta livelli di affidabilità già elevati per la protezione dai guasti ordinari, ampi margini di miglioramento sono disponibili intervenendo sulla scelta dei componenti in funzione della potenza di illuminazione e in relazione alla resistenza al fuoco.

La rilevanza della disponibilità e dell’affidabilità dei si-stemi vitali sulla sicurezza delle gallerie ferroviarie / Rossi, Giuliano; Lombardi, Mara; Guarascio, Massimo; Sciarretta, Nicolo'. - STAMPA. - IV:(2015), pp. 275-284. (Intervento presentato al convegno IV Convegno Nazionale SICUREZZA ED ESERCIZIO FERROVIARIO Soluzioni e Strategie per lo Sviluppo del Trasporto Ferroviario tenutosi a Roma nel 2 ottobre 2015).

La rilevanza della disponibilità e dell’affidabilità dei si-stemi vitali sulla sicurezza delle gallerie ferroviarie

Rossi, Giuliano;LOMBARDI, MARA;GUARASCIO, Massimo;SCIARRETTA, NICOLO'
2015

Abstract

The paper shows the results obtained by measuring the variation in the risk indi-cators when the fire in tunnel induces railway accident. According to the principle of safety performance effectiveness, the analysis of reliability, availability and rele-vance of subsystems making up the tunnel system, was based on quantitative risk analysis (QRA) and approach RAMS. By modifying the design of safety power sys-tem, comparative evaluations on the risk level were conducted in order to obtaining useful results to the effectiveness of the emergency management in the tunnel in case of fire. The architecture of wiring system shows already high levels of reliabil-ity to protection from simple faults; substantial rooms for improvement are avail-able based on the power of lighting and on the fire resistance.
2015
IV Convegno Nazionale SICUREZZA ED ESERCIZIO FERROVIARIO Soluzioni e Strategie per lo Sviluppo del Trasporto Ferroviario
Il lavoro propone i risultati ottenuti da una valutazione di elasticità del rischio in caso di incidente ferroviario in galleria e di incendio in particolare. Le verifiche di affidabilità, di disponibilità e di rilevanza dei sottosistemi costituenti il sistema gal-leria, condotte mediante analisi di rischio quantitativa (QRA) e approccio RAMS, sono sviluppate nel rispetto del principio di effettività delle prestazioni di sicurezza. Nel dettaglio sono state condotte valutazioni comparative sul rischio al variare del design dei cablaggi di forza motrice di impianti di sicurezza, ottenendo risultati utili a migliorare la gestione dell’emergenza in galleria in caso di incendio. Lo studio condotto ha evidenziato che mentre l’architettura tipo del cablaggio presenta livelli di affidabilità già elevati per la protezione dai guasti ordinari, ampi margini di miglioramento sono disponibili intervenendo sulla scelta dei componenti in funzione della potenza di illuminazione e in relazione alla resistenza al fuoco.
Affidabilità, Disponibilità, Gallerie ferroviarie, Sicurezza
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
La rilevanza della disponibilità e dell’affidabilità dei si-stemi vitali sulla sicurezza delle gallerie ferroviarie / Rossi, Giuliano; Lombardi, Mara; Guarascio, Massimo; Sciarretta, Nicolo'. - STAMPA. - IV:(2015), pp. 275-284. (Intervento presentato al convegno IV Convegno Nazionale SICUREZZA ED ESERCIZIO FERROVIARIO Soluzioni e Strategie per lo Sviluppo del Trasporto Ferroviario tenutosi a Roma nel 2 ottobre 2015).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/796588
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact