BACKGROUND: High-risk hypertrophic cardiomyopathy (HCM) patients benefit from the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) may provide comparable protection while avoiding the shortcomings of transvenous (TV) leads. We assessed S-ICD eligibility according to surface ECG screening test in a cohort of high-risk HCM patients. METHODS AND RESULTS: 47 HCM patients (3 S-ICD candidates; 41 TV-ICD patients without pacing indication; and 3 pacemaker-dependent TV-ICD patients) underwent 4 screening protocols: standard (n = 44); exercise (n = 33); continuous pacing (n = 44); alternating paced/spontaneous QRS (n = 41). Of the 44 patients in the standard screening group, 41 (93%) were eligible. Max LV thickness was inversely related to the number of qualifying leads (3 leads: 21 ± 4 mm; 2 leads: 22 ± 6 mm; 1 lead: 25 ± 6 mm; no leads: 28 ± 11 mm; P = 0.07). Of the 33 patients in the exercise group, 5 were ineligible (3 after exercise). Of these, 2 became eligible after moving sternal electrodes from the left to the right parasternal line (eligibility rate: 30/33; 91%). Of the 44 patients in the continuous pacing group, 28 (64%) were eligible, 8 of which with right parasternal electrodes. In the paced/spontaneous QRS group (n = 41), 21 patients (51%) had at least 1 eligible lead during pacing and retained compatibility on the same lead during spontaneous rhythm, 5 of which with right parasternal electrodes. CONCLUSIONS: S-ICD screening failure is low in HCM, provided that patients with severe hypertrophy are carefully evaluated. Exercise test should be performed and right parasternal leads tested. Pacemaker patients display lower eligibility rate.

Eligibility for the subcutaneous implantable cardioverter-defibrillator in patients with hypertrophic cardiomyopathy / Francia, Pietro; Adduci, Carmen; Palano, Francesca; Semprini, Lorenzo; Serdoz, Andrea; Montesanti, Dalma; Santini, Daria; Musumeci, Beatrice; Salvati, Adriano; Volpe, Massimo; Autore, Camillo. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - 26:8(2015), pp. 893-899. [10.1111/jce.12714]

Eligibility for the subcutaneous implantable cardioverter-defibrillator in patients with hypertrophic cardiomyopathy

FRANCIA, Pietro;ADDUCI, CARMEN;PALANO, FRANCESCA;SEMPRINI, LORENZO;SERDOZ, ANDREA;MONTESANTI, DALMA;SANTINI, Daria;Musumeci, Beatrice;VOLPE, Massimo;AUTORE, Camillo
2015

Abstract

BACKGROUND: High-risk hypertrophic cardiomyopathy (HCM) patients benefit from the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) may provide comparable protection while avoiding the shortcomings of transvenous (TV) leads. We assessed S-ICD eligibility according to surface ECG screening test in a cohort of high-risk HCM patients. METHODS AND RESULTS: 47 HCM patients (3 S-ICD candidates; 41 TV-ICD patients without pacing indication; and 3 pacemaker-dependent TV-ICD patients) underwent 4 screening protocols: standard (n = 44); exercise (n = 33); continuous pacing (n = 44); alternating paced/spontaneous QRS (n = 41). Of the 44 patients in the standard screening group, 41 (93%) were eligible. Max LV thickness was inversely related to the number of qualifying leads (3 leads: 21 ± 4 mm; 2 leads: 22 ± 6 mm; 1 lead: 25 ± 6 mm; no leads: 28 ± 11 mm; P = 0.07). Of the 33 patients in the exercise group, 5 were ineligible (3 after exercise). Of these, 2 became eligible after moving sternal electrodes from the left to the right parasternal line (eligibility rate: 30/33; 91%). Of the 44 patients in the continuous pacing group, 28 (64%) were eligible, 8 of which with right parasternal electrodes. In the paced/spontaneous QRS group (n = 41), 21 patients (51%) had at least 1 eligible lead during pacing and retained compatibility on the same lead during spontaneous rhythm, 5 of which with right parasternal electrodes. CONCLUSIONS: S-ICD screening failure is low in HCM, provided that patients with severe hypertrophy are carefully evaluated. Exercise test should be performed and right parasternal leads tested. Pacemaker patients display lower eligibility rate.
2015
hypertrophic cardiomyopathy; implantable cardioverter defibrillator; subcutaneous icd, sudden death; transvenous icd; cardiology and cardiovascular medicine; physiology (medical)
01 Pubblicazione su rivista::01a Articolo in rivista
Eligibility for the subcutaneous implantable cardioverter-defibrillator in patients with hypertrophic cardiomyopathy / Francia, Pietro; Adduci, Carmen; Palano, Francesca; Semprini, Lorenzo; Serdoz, Andrea; Montesanti, Dalma; Santini, Daria; Musumeci, Beatrice; Salvati, Adriano; Volpe, Massimo; Autore, Camillo. - In: JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY. - ISSN 1045-3873. - 26:8(2015), pp. 893-899. [10.1111/jce.12714]
File allegati a questo prodotto
File Dimensione Formato  
Francia_Eligibility_2015.pdf

solo gestori archivio

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 468.76 kB
Formato Adobe PDF
468.76 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/794978
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 40
  • ???jsp.display-item.citation.isi??? 42
social impact