This paper presents an impedance plethysmography system suitable to perform a continuous monitoring of human breath activity. The problem of motion artifact is mitigated through the use of a correction technique exploiting an additional inertial sensor able to detect movements of the arms of the subject under test. The correction algorithm is based on a simple correlation technique and only requires a very brief training at the beginning of the acquisition session, with the monitored subject performing random movements in apnea condition. Application of the proposed system to a healthy adult volunteer demonstrates the potentiality of the correction algorithm, which, thanks to its extreme simplicity and low computational cost, is a suitable candidate for implementation in a low-cost and portable monitoring system.

Impedance plethysmography system with inertial measurement units for motion artefact reduction: Application to continuous breath activity monitoring / Piuzzi, Emanuele; Capuano, A.; Pisa, Stefano; Cappa, Paolo; Patané, F.; Rossi, S.; Giaquinto, N.; D’Aucelli, G. M.. - ELETTRONICO. - (2015), pp. 386-390. (Intervento presentato al convegno 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) tenutosi a Turin, Italy nel 7-9 May 2015) [10.1109/MeMeA.2015.7145233].

Impedance plethysmography system with inertial measurement units for motion artefact reduction: Application to continuous breath activity monitoring

PIUZZI, Emanuele;PISA, Stefano;CAPPA, Paolo;
2015

Abstract

This paper presents an impedance plethysmography system suitable to perform a continuous monitoring of human breath activity. The problem of motion artifact is mitigated through the use of a correction technique exploiting an additional inertial sensor able to detect movements of the arms of the subject under test. The correction algorithm is based on a simple correlation technique and only requires a very brief training at the beginning of the acquisition session, with the monitored subject performing random movements in apnea condition. Application of the proposed system to a healthy adult volunteer demonstrates the potentiality of the correction algorithm, which, thanks to its extreme simplicity and low computational cost, is a suitable candidate for implementation in a low-cost and portable monitoring system.
2015
2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA)
accelerometer; bioimpedance; biomedical monitoring; biomedical signal processing; correlation; plethysmography
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Impedance plethysmography system with inertial measurement units for motion artefact reduction: Application to continuous breath activity monitoring / Piuzzi, Emanuele; Capuano, A.; Pisa, Stefano; Cappa, Paolo; Patané, F.; Rossi, S.; Giaquinto, N.; D’Aucelli, G. M.. - ELETTRONICO. - (2015), pp. 386-390. (Intervento presentato al convegno 2015 IEEE International Symposium on Medical Measurements and Applications (MeMeA) tenutosi a Turin, Italy nel 7-9 May 2015) [10.1109/MeMeA.2015.7145233].
File allegati a questo prodotto
File Dimensione Formato  
Piuzzi_Impedance-plethysmography_2015.pdf

solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/788104
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 10
social impact