Objective To evaluate the impact of a hybrid control on usability of a P300-based brain-computer interface (BCI) system that was designed to control an assistive technology software and was integrated with an electromyographic channel for error correction. Design Proof-of-principle study with a convenience sample. Setting Neurologic rehabilitation hospital. Participants Participants (N=11) in this pilot study included healthy (n=8) and severely motor impaired (n=3) persons. The 3 people with severe motor disability were identified as potential candidates to benefit from the proposed hybrid BCI system for communication and environmental interaction. Interventions To eventually investigate the improvement in usability, we compared 2 modalities of BCI system control: a P300-based and a hybrid P300 electromyographic-based mode of control. Main Outcome Measures System usability was evaluated according to the following outcome measures within 3 domains: (1) effectiveness (overall system accuracy and P300-based BCI accuracy); (2) efficiency (throughput time and users' workload); and (3) satisfaction (users' satisfaction). We also considered the information transfer rate and time for selection. Results Findings obtained in healthy participants were in favor of a higher usability of the hybrid control as compared with the nonhybrid. A similar trend was indicated by the observational results gathered from each of the 3 potential end-users. Conclusions The proposed hybrid BCI control modality could provide end-users with severe motor disability with an option to exploit some residual muscular activity, which could not be fully reliable for properly controlling an assistive technology device. The findings reported in this pilot study encourage the implementation of a clinical trial involving a large cohort of end-users. © 2015 American Congress of Rehabilitation Medicine.

Hybrid P300-based brain-computer interface to improve usability for people with severe motor disability: electromyographic signals for error correction during a spelling task / Riccio, Angela; Holz Elisa, Mira; Aricò, Pietro; Leotta, Francesco; Aloise, Fabio; Desideri, Lorenzo; Rimondini, Matteo; Kübler, Andrea; Mattia, Donatella; Cincotti, Febo. - In: ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION. - ISSN 0003-9993. - STAMPA. - 96:3 (Suppl 1)(2015), pp. S54-S61. [10.1016/j.apmr.2014.05.029]

Hybrid P300-based brain-computer interface to improve usability for people with severe motor disability: electromyographic signals for error correction during a spelling task

Riccio Angela
;
Aricò Pietro;Leotta Francesco;Aloise Fabio;Cincotti Febo
2015

Abstract

Objective To evaluate the impact of a hybrid control on usability of a P300-based brain-computer interface (BCI) system that was designed to control an assistive technology software and was integrated with an electromyographic channel for error correction. Design Proof-of-principle study with a convenience sample. Setting Neurologic rehabilitation hospital. Participants Participants (N=11) in this pilot study included healthy (n=8) and severely motor impaired (n=3) persons. The 3 people with severe motor disability were identified as potential candidates to benefit from the proposed hybrid BCI system for communication and environmental interaction. Interventions To eventually investigate the improvement in usability, we compared 2 modalities of BCI system control: a P300-based and a hybrid P300 electromyographic-based mode of control. Main Outcome Measures System usability was evaluated according to the following outcome measures within 3 domains: (1) effectiveness (overall system accuracy and P300-based BCI accuracy); (2) efficiency (throughput time and users' workload); and (3) satisfaction (users' satisfaction). We also considered the information transfer rate and time for selection. Results Findings obtained in healthy participants were in favor of a higher usability of the hybrid control as compared with the nonhybrid. A similar trend was indicated by the observational results gathered from each of the 3 potential end-users. Conclusions The proposed hybrid BCI control modality could provide end-users with severe motor disability with an option to exploit some residual muscular activity, which could not be fully reliable for properly controlling an assistive technology device. The findings reported in this pilot study encourage the implementation of a clinical trial involving a large cohort of end-users. © 2015 American Congress of Rehabilitation Medicine.
2015
ALS (amyotrophic lateral sclerosis); assistive technology; brain injuries; brain-computer interfaces; event-related potentials; P300; rehabilitation; adult; disabled persons; electroencephalography; female; humans; male; middle aged; nervous system diseases; patient satisfaction; pilot projects; rehabilitation centers; self-help devices; user-computer interface; brain-computer interfaces
01 Pubblicazione su rivista::01a Articolo in rivista
Hybrid P300-based brain-computer interface to improve usability for people with severe motor disability: electromyographic signals for error correction during a spelling task / Riccio, Angela; Holz Elisa, Mira; Aricò, Pietro; Leotta, Francesco; Aloise, Fabio; Desideri, Lorenzo; Rimondini, Matteo; Kübler, Andrea; Mattia, Donatella; Cincotti, Febo. - In: ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION. - ISSN 0003-9993. - STAMPA. - 96:3 (Suppl 1)(2015), pp. S54-S61. [10.1016/j.apmr.2014.05.029]
File allegati a questo prodotto
File Dimensione Formato  
Riccio_Hybrid-P300-Based_2015.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.81 MB
Formato Adobe PDF
1.81 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/787665
Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 45
social impact