IMPORTANCE: This study confirmed the long-term outcomes of the ZB5M phakic intraocular lens (PIOL). OBJECTIVE: To evaluate the potential long-term risk associated with ZB5M PIOL implantation. DESIGN, SETTING, AND PARTICIPANTS: A retrospective, nonrandomized, consecutive cohort study of a total of 208 eyes implanted with ZB5M PIOLs at VISSUM Corporación Oftalmológica de Alicante between 1990 and 1996 identified through surgical records (208 eyes of 123 patients); 50 of these patients (97 eyes) had available records and follow-up. INTERVENTION: ZB5M PIOL implantation. MAIN OUTCOMES AND MEASURES: To evaluate the incidence and onset of each complication during the follow-up and risk factors and causes for loss of visual acuity. RESULTS: Mean (SD) preoperative spherical equivalent refraction was -19.36 (6.7) diopters and at the end of follow-up, it was -1.4 (2.6) diopters. Mean (SD) best-corrected visual acuity at the preoperative visit was 0.35 (0.2) decimal and at the end of follow-up, 0.

Follow-up Study of More Than 15 Years of an Angle-Supported Phakic Intraocular Lens Model (ZB5M) for High Myopia: Outcomes and Complications / Alio, Jl; Abbouda, Alessandro; Peña Garcia, P; Huseynli, S.. - In: JAMA OPHTHALMOLOGY. - ISSN 2168-6165. - (2013). [10.1001/jamaophthalmol.2013.5595]

Follow-up Study of More Than 15 Years of an Angle-Supported Phakic Intraocular Lens Model (ZB5M) for High Myopia: Outcomes and Complications.

ABBOUDA, ALESSANDRO;
2013

Abstract

IMPORTANCE: This study confirmed the long-term outcomes of the ZB5M phakic intraocular lens (PIOL). OBJECTIVE: To evaluate the potential long-term risk associated with ZB5M PIOL implantation. DESIGN, SETTING, AND PARTICIPANTS: A retrospective, nonrandomized, consecutive cohort study of a total of 208 eyes implanted with ZB5M PIOLs at VISSUM Corporación Oftalmológica de Alicante between 1990 and 1996 identified through surgical records (208 eyes of 123 patients); 50 of these patients (97 eyes) had available records and follow-up. INTERVENTION: ZB5M PIOL implantation. MAIN OUTCOMES AND MEASURES: To evaluate the incidence and onset of each complication during the follow-up and risk factors and causes for loss of visual acuity. RESULTS: Mean (SD) preoperative spherical equivalent refraction was -19.36 (6.7) diopters and at the end of follow-up, it was -1.4 (2.6) diopters. Mean (SD) best-corrected visual acuity at the preoperative visit was 0.35 (0.2) decimal and at the end of follow-up, 0.
2013
01 Pubblicazione su rivista::01a Articolo in rivista
Follow-up Study of More Than 15 Years of an Angle-Supported Phakic Intraocular Lens Model (ZB5M) for High Myopia: Outcomes and Complications / Alio, Jl; Abbouda, Alessandro; Peña Garcia, P; Huseynli, S.. - In: JAMA OPHTHALMOLOGY. - ISSN 2168-6165. - (2013). [10.1001/jamaophthalmol.2013.5595]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/780022
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 10
social impact