The Self-Care of Heart Failure Index (SCHFI) is used widely, but issues with reliability have been evident. Cronbach alpha coefficient is usually used to assess reliability, but this approach assumes a unidimensional scale. The purpose of this article is to address the dimensionality and internal consistency reliability of the SCHFI. This was a secondary analysis of data from 629 adults with heart failure enrolled in three separate studies conducted in the northeastern and northwestern United States. Following testing for scale dimensionality using confirmatory factor analysis, reliability was tested using coefficient alpha and alternative options. Confirmatory factor analysis demonstrated that: (a) the Self-Care Maintenance Scale has a multidimensional four-factor structure; (b) the Self-Care Management Scale has a two-factor structure, but the primary factors loaded on a common higherorder factor; and (c) the Self-Care Confidence Scale is unidimensional. Reliability estimates for the three scales, obtained with methods compatible with each scale's dimensionality, were adequate or high. The results of the analysis demonstrate that issues of dimensionality and reliability cannot be separated. Appropriate estimates of reliability that are consistent with the dimensionality of the scale must be used. In the case of the SCHFI, coefficient alpha should not be used to assess reliability of the self-care maintenance and the self-care management scales, due to their multidimensionality. When performing psychometric evaluations, we recommend testing dimensionality before assessing reliability, as well using multiple indices of reliability, such as model-based internal consistency, composite reliability, and omega and maximal reliability coefficients.

Dimensionality and reliability of the self-care of heart failure index scales: further evidence from confirmatory factor analysis / Barbaranelli, Claudio; Lee, C.; Vellone, E.; Riegel, B.. - In: RESEARCH IN NURSING & HEALTH. - ISSN 0160-6891. - STAMPA. - 37:(2014), pp. 524-537. [10.1002/nur.21623]

Dimensionality and reliability of the self-care of heart failure index scales: further evidence from confirmatory factor analysis

BARBARANELLI, Claudio;
2014

Abstract

The Self-Care of Heart Failure Index (SCHFI) is used widely, but issues with reliability have been evident. Cronbach alpha coefficient is usually used to assess reliability, but this approach assumes a unidimensional scale. The purpose of this article is to address the dimensionality and internal consistency reliability of the SCHFI. This was a secondary analysis of data from 629 adults with heart failure enrolled in three separate studies conducted in the northeastern and northwestern United States. Following testing for scale dimensionality using confirmatory factor analysis, reliability was tested using coefficient alpha and alternative options. Confirmatory factor analysis demonstrated that: (a) the Self-Care Maintenance Scale has a multidimensional four-factor structure; (b) the Self-Care Management Scale has a two-factor structure, but the primary factors loaded on a common higherorder factor; and (c) the Self-Care Confidence Scale is unidimensional. Reliability estimates for the three scales, obtained with methods compatible with each scale's dimensionality, were adequate or high. The results of the analysis demonstrate that issues of dimensionality and reliability cannot be separated. Appropriate estimates of reliability that are consistent with the dimensionality of the scale must be used. In the case of the SCHFI, coefficient alpha should not be used to assess reliability of the self-care maintenance and the self-care management scales, due to their multidimensionality. When performing psychometric evaluations, we recommend testing dimensionality before assessing reliability, as well using multiple indices of reliability, such as model-based internal consistency, composite reliability, and omega and maximal reliability coefficients.
2014
heart failure, psychometrics, reliability, factor analysis, self-care, measurement, instrument validation
01 Pubblicazione su rivista::01a Articolo in rivista
Dimensionality and reliability of the self-care of heart failure index scales: further evidence from confirmatory factor analysis / Barbaranelli, Claudio; Lee, C.; Vellone, E.; Riegel, B.. - In: RESEARCH IN NURSING & HEALTH. - ISSN 0160-6891. - STAMPA. - 37:(2014), pp. 524-537. [10.1002/nur.21623]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/778378
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 35
  • Scopus 94
  • ???jsp.display-item.citation.isi??? 88
social impact