The paper proposes the main results obtained from the Quantitative Risk Analysis developed on an existing tunnel, according to the Ministerial Decree "Safety of railway tunnels" (October 28 2005). The fire produces the most severe scenario among the possible emergencies in confined area, thus the regulations in Europe and in Italy (Technical Specifications for Interoperability, Decision December 20th 2007, Ministerial Decree October 28th 2005) obligate to direct adoption of measures and devices for prevention and protection to reduce the probability of occurrence of this specific critical scenario and the containment of the fire effects. To mitigate the damage, the difficulty of providing an effective external rescue in a short time involves supplementary safety measures aimed at improving the process of self-rescue.

Fire protection of emergency electrical devices: effect on the level of risk. Case study of rail tunnel / Lombardi, Mara; Rossi, Giuliano. - STAMPA. - 151:(2015), pp. 73-83. (Intervento presentato al convegno 6th International Conference on Safety and Security Engineering tenutosi a Opatija nel 6-8 maggio 2015) [10.2495/SAFE150011].

Fire protection of emergency electrical devices: effect on the level of risk. Case study of rail tunnel

LOMBARDI, MARA;Rossi, Giuliano
2015

Abstract

The paper proposes the main results obtained from the Quantitative Risk Analysis developed on an existing tunnel, according to the Ministerial Decree "Safety of railway tunnels" (October 28 2005). The fire produces the most severe scenario among the possible emergencies in confined area, thus the regulations in Europe and in Italy (Technical Specifications for Interoperability, Decision December 20th 2007, Ministerial Decree October 28th 2005) obligate to direct adoption of measures and devices for prevention and protection to reduce the probability of occurrence of this specific critical scenario and the containment of the fire effects. To mitigate the damage, the difficulty of providing an effective external rescue in a short time involves supplementary safety measures aimed at improving the process of self-rescue.
2015
6th International Conference on Safety and Security Engineering
fire safety engineering, emergency lighting, rail tunnel, safety electrical system, quantitative risk analysis
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Fire protection of emergency electrical devices: effect on the level of risk. Case study of rail tunnel / Lombardi, Mara; Rossi, Giuliano. - STAMPA. - 151:(2015), pp. 73-83. (Intervento presentato al convegno 6th International Conference on Safety and Security Engineering tenutosi a Opatija nel 6-8 maggio 2015) [10.2495/SAFE150011].
File allegati a questo prodotto
File Dimensione Formato  
Lombardi_Fire-protection_2015.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 977.21 kB
Formato Adobe PDF
977.21 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/769609
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact