The aim of this research was to test the correctness of response of a superoxide dismutase amperometric biosensor used for the purpose of measuring and ranking the total antioxidant capacity of several systematically analysed mixed berries. Several methods are described in the literature for determining antioxidant capacity, each culminating in the construction of an antioxidant capacity scale and each using its own unit of measurement. It was therefore endeavoured to correlate and compare the results obtained using the present amperometric biosensor method with those resulting from two other different methods for determining the total antioxidant capacity selected from among those more frequently cited in the literature. The purpose was to establish a methodological approach consisting in the simultaneous application of different methods that it would be possible to use to obtain an accurate estimation of the total antioxidant capacity of different mixed berries and the food products

Amperometric enzyme sensor to check the total antioxidant capacity of several mixed berries. comparison with two other spectrophotometric and fluorimetric methods / TOMASSETTI, Mauro; Maruschka, Serone; Riccardo, Angeloni; CAMPANELLA, Luigi; Elisa, Mazzone. - In: SENSORS. - ISSN 1424-8220. - 15:(2015), pp. 3435-3452. [10.3390/s150203435]

Amperometric enzyme sensor to check the total antioxidant capacity of several mixed berries. comparison with two other spectrophotometric and fluorimetric methods

TOMASSETTI, Mauro
;
CAMPANELLA, Luigi;
2015

Abstract

The aim of this research was to test the correctness of response of a superoxide dismutase amperometric biosensor used for the purpose of measuring and ranking the total antioxidant capacity of several systematically analysed mixed berries. Several methods are described in the literature for determining antioxidant capacity, each culminating in the construction of an antioxidant capacity scale and each using its own unit of measurement. It was therefore endeavoured to correlate and compare the results obtained using the present amperometric biosensor method with those resulting from two other different methods for determining the total antioxidant capacity selected from among those more frequently cited in the literature. The purpose was to establish a methodological approach consisting in the simultaneous application of different methods that it would be possible to use to obtain an accurate estimation of the total antioxidant capacity of different mixed berries and the food products
2015
antioxidant capacity; amperometric measurement; biosensor; fluorimetric; spectrophotometric; methods
01 Pubblicazione su rivista::01a Articolo in rivista
Amperometric enzyme sensor to check the total antioxidant capacity of several mixed berries. comparison with two other spectrophotometric and fluorimetric methods / TOMASSETTI, Mauro; Maruschka, Serone; Riccardo, Angeloni; CAMPANELLA, Luigi; Elisa, Mazzone. - In: SENSORS. - ISSN 1424-8220. - 15:(2015), pp. 3435-3452. [10.3390/s150203435]
File allegati a questo prodotto
File Dimensione Formato  
Tomassetti_Amperometric_2015.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.4 MB
Formato Adobe PDF
1.4 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/763919
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 16
social impact