Abstract AIM: To assess eosinophil cationic protein (ECP) and C-reactive protein (CRP) serum levels at three time points according to different stent types. METHODS: 54 patients (age 64 ± 10 years, male 78%), undergoing Bare Metal Stent (BMS) (n = 11), mammalian Target Of Rapamycin (mTOR)-inhibitor DES (n = 27) and mTOR-inhibitor bioabsorbable DES (BES) (n = 16) implantation for stable angina (SA) or non-ST-elevation acute coronary syndromes (NSTE-ACS), were prospectively enrolled. ECP and CRP serum levels were assessed before revascularization, at 1-month and at 1-year after the procedure. Moreover, 21 patients found to have inducible ischemia or angina symptoms at 6 month-stress test underwent 1-year follow-up (FU) angiography. RESULTS: Baseline and 1-month ECP levels were similar among the 3 groups, whilst 1-year ECP was significantly higher in m-TOR-DES [8.61 (6.55-19.77) μg/ml] compared with m-TOR-BES [2.03 (1.78-5.53) μg/ml] and BMS-treated patients [2.23 (1.45-8.95) μg/ml] (p = 0.02), without significant difference between BES and BMS. CRP was similar among the 3 groups at all time points. 1-year ECP significantly correlated with late loss in patients undergoing FU angiography (r = 0.64, p = 0.002), while CRP did not (p = NS). CONCLUSIONS: Our finding suggests that mTOR-DES stent type is associated with an increase of ECP levels at 1-year, possibly reflecting a persistent eosinophil activation triggered by permanent polymer.

Permanent polymer of drug eluting stents increases eosinophil cationic protein levels following percutaneous coronary intervention independently of C-reactive protein / Niccoli, G; Calvieri, Camilla; Minelli, S; Copponi, G; Montone, R; Imaeva, A; Roberto, M; Cosentino, N; Crea, F.. - In: ATHEROSCLEROSIS. - ISSN 1879-1484. - (2014).

Permanent polymer of drug eluting stents increases eosinophil cationic protein levels following percutaneous coronary intervention independently of C-reactive protein.

CALVIERI, CAMILLA;
2014

Abstract

Abstract AIM: To assess eosinophil cationic protein (ECP) and C-reactive protein (CRP) serum levels at three time points according to different stent types. METHODS: 54 patients (age 64 ± 10 years, male 78%), undergoing Bare Metal Stent (BMS) (n = 11), mammalian Target Of Rapamycin (mTOR)-inhibitor DES (n = 27) and mTOR-inhibitor bioabsorbable DES (BES) (n = 16) implantation for stable angina (SA) or non-ST-elevation acute coronary syndromes (NSTE-ACS), were prospectively enrolled. ECP and CRP serum levels were assessed before revascularization, at 1-month and at 1-year after the procedure. Moreover, 21 patients found to have inducible ischemia or angina symptoms at 6 month-stress test underwent 1-year follow-up (FU) angiography. RESULTS: Baseline and 1-month ECP levels were similar among the 3 groups, whilst 1-year ECP was significantly higher in m-TOR-DES [8.61 (6.55-19.77) μg/ml] compared with m-TOR-BES [2.03 (1.78-5.53) μg/ml] and BMS-treated patients [2.23 (1.45-8.95) μg/ml] (p = 0.02), without significant difference between BES and BMS. CRP was similar among the 3 groups at all time points. 1-year ECP significantly correlated with late loss in patients undergoing FU angiography (r = 0.64, p = 0.002), while CRP did not (p = NS). CONCLUSIONS: Our finding suggests that mTOR-DES stent type is associated with an increase of ECP levels at 1-year, possibly reflecting a persistent eosinophil activation triggered by permanent polymer.
2014
01 Pubblicazione su rivista::01a Articolo in rivista
Permanent polymer of drug eluting stents increases eosinophil cationic protein levels following percutaneous coronary intervention independently of C-reactive protein / Niccoli, G; Calvieri, Camilla; Minelli, S; Copponi, G; Montone, R; Imaeva, A; Roberto, M; Cosentino, N; Crea, F.. - In: ATHEROSCLEROSIS. - ISSN 1879-1484. - (2014).
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/762123
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 5
social impact