Current studies concerning statistical elaboration and review of existing experimental results in databases, usually include only the characteristic maximum bearing stress and corresponding strain values as well as the failure values. In cases of uniform confinement failure values may be defined at 20% or 15% drop of maximum load or when the FRP jacket is fractured. Several recommendations include additional failure criteria related to lateral strain level or axial strain level in order to ensure the integrity of the columns or avoidance of shear failures among else. An experimental database based on the whole stress-strain response curves is presented, providing significant data necessary for the extensive assessment of the existing design models. The experimental database contains information on: a) the failure stress and strain values, b) on the stress and strain values at the level of 0.4% lateral strain as well as c) on the stress at the level of 1% axial strain. FRP confinement strength models recommended by existing guidelines are compared against experimental values.

Upgraded experimental database of uniformly FRP confined concrete columns for assessment of existing recommendations / Rousakis, T.; Nistico', Nicola; Karabinis, A.. - ELETTRONICO. - (2012), pp. 1-8. (Intervento presentato al convegno The 6th International Conference on FRP Composites in Civil Engineering tenutosi a Roma - Italy nel June).

Upgraded experimental database of uniformly FRP confined concrete columns for assessment of existing recommendations

NISTICO', Nicola;
2012

Abstract

Current studies concerning statistical elaboration and review of existing experimental results in databases, usually include only the characteristic maximum bearing stress and corresponding strain values as well as the failure values. In cases of uniform confinement failure values may be defined at 20% or 15% drop of maximum load or when the FRP jacket is fractured. Several recommendations include additional failure criteria related to lateral strain level or axial strain level in order to ensure the integrity of the columns or avoidance of shear failures among else. An experimental database based on the whole stress-strain response curves is presented, providing significant data necessary for the extensive assessment of the existing design models. The experimental database contains information on: a) the failure stress and strain values, b) on the stress and strain values at the level of 0.4% lateral strain as well as c) on the stress at the level of 1% axial strain. FRP confinement strength models recommended by existing guidelines are compared against experimental values.
2012
The 6th International Conference on FRP Composites in Civil Engineering
Fiber reinforced plastics ; Reinforced concrete; concrete cylinders
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Upgraded experimental database of uniformly FRP confined concrete columns for assessment of existing recommendations / Rousakis, T.; Nistico', Nicola; Karabinis, A.. - ELETTRONICO. - (2012), pp. 1-8. (Intervento presentato al convegno The 6th International Conference on FRP Composites in Civil Engineering tenutosi a Roma - Italy nel June).
File allegati a questo prodotto
File Dimensione Formato  
Rousakis_Upgraded_2012.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 241.17 kB
Formato Adobe PDF
241.17 kB Adobe PDF   Contatta l'autore

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/759831
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact