The nature and causes of corrosive sulfur induced failures are examined in oil-filled transformers and shunt reactors. Copper sulfide, which is formed when the corrosive sulfur in a mineral oil reacts with the copper conductors, is likely to diffuse into the paper tapes insulating the conductors. Since copper sulfide is partially conducting, the dielectric losses of the contaminated oil-impregnated-paper tapes are markedly increased; paper tapes in close proximity to the copper conductors are found to attain tan delta values > 1.0 even at room temperature. It is highly likely that thermal instabilities develop at those sites at operating temperatures, leading to increased loss currents and, ultimately, short circuits between the turns. This sequence of events is substantiated by evidence from the field, which indicates large areas of thermally degraded insulations and charred breakdown regions along the coils, the extent of which becomes more pronounced at higher operating temperatures (toward the top of the windings).

Corrosive Sulfur Induced Failures in Oil-Filled Electrical Power Transformers and Shunt Reactors / F., Scatiggio; V., Tumiatti; R., Maina; Pompili, Massimo; R., Bartnikas. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - 24:3(2009), pp. 1240-1248. [10.1109/tpwrd.2008.2005369]

Corrosive Sulfur Induced Failures in Oil-Filled Electrical Power Transformers and Shunt Reactors

POMPILI, Massimo;
2009

Abstract

The nature and causes of corrosive sulfur induced failures are examined in oil-filled transformers and shunt reactors. Copper sulfide, which is formed when the corrosive sulfur in a mineral oil reacts with the copper conductors, is likely to diffuse into the paper tapes insulating the conductors. Since copper sulfide is partially conducting, the dielectric losses of the contaminated oil-impregnated-paper tapes are markedly increased; paper tapes in close proximity to the copper conductors are found to attain tan delta values > 1.0 even at room temperature. It is highly likely that thermal instabilities develop at those sites at operating temperatures, leading to increased loss currents and, ultimately, short circuits between the turns. This sequence of events is substantiated by evidence from the field, which indicates large areas of thermally degraded insulations and charred breakdown regions along the coils, the extent of which becomes more pronounced at higher operating temperatures (toward the top of the windings).
2009
corrosive sulfur; dibenzyl disulfide (dbds); failures; oil insulation; standardization; transformers/shunt reactors
01 Pubblicazione su rivista::01a Articolo in rivista
Corrosive Sulfur Induced Failures in Oil-Filled Electrical Power Transformers and Shunt Reactors / F., Scatiggio; V., Tumiatti; R., Maina; Pompili, Massimo; R., Bartnikas. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - 24:3(2009), pp. 1240-1248. [10.1109/tpwrd.2008.2005369]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/75758
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 131
  • ???jsp.display-item.citation.isi??? 102
social impact