Abstract PURPOSE: Tibia torsion may influence the accuracy of extramedullary instrumentations in total knee arthroplasty (TKA). This study assessed whether the effect of tibial torsion may be overcome using a surgical technique in which the extramedullary rod is aligned to reference points at the proximal tibia only. METHODS: A consecutive series of 94 knees that underwent TKA were analyzed. In the first 47 knees (group 1), a standard procedure for tibial component alignment was performed while in the second group of 47 knees, a modified surgical technique was used including the alignment of the extramedullary rod to the reference points at the proximal tibia only (group 2). Lower limb, femoral, and tibial component alignment were measured on postoperative long-leg radiographs. RESULTS: Femorotibial mechanical axes angles were similar in the two groups. Femoral component alignment also did not differ between the groups. A neutral alignment of the tibial component was achieved in 17

Purpose Tibia torsion may influence the accuracy of extramedullary instrumentations in total knee arthroplasty (TKA). This study assessed whether the effect of tibial torsion may be overcome using a surgical technique in which the extramedullary rod is aligned to reference points at the proximal tibia only. Methods A consecutive series of 94 knees that underwent TKA were analyzed. In the first 47 knees (group 1), a standard procedure for tibial component alignment was performed while in the second group of 47 knees, a modified surgical technique was used including the alignment of the extramedullary rod to the reference points at the proximal tibia only (group 2). Lower limb, femoral, and tibial component alignment were measured on postoperative long-leg radiographs. Results Femorotibial mechanical axes angles were similar in the two groups. Femoral component alignment also did not differ between the groups. A neutral alignment of the tibial component was achieved in 17 and 34 % of the knees in group 1 and group 2, respectively (p = 0.04). A malalignment of the tibial component >3° was found in 34 % of knees in group 1 compared with 4 % of those in group 2 (p = 0.0001). Conclusions Coronal alignment of the tibial component may improve by setting the extramedullary rod in line with anatomical references in the proximal tibia only. This technique appears to bypass the influence of tibial torsion on the alignment of the extramedullary guide at the distal tibia. The clinical relevance of the study is that using this technique, the rate of malalignment of the tibial component may be reduced compared to a standard technique in which a fixed reference is used at the ankle joint

Improving tibial component alignment in total knee arthroplasty / Cinotti, Gianluca; Sessa, P; D'Arino, A; Ripani, Fr; Giannicola, G.. - In: KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY. - ISSN 0942-2056. - STAMPA. - (2014), p. .... [10.1007/s00167-014-3236-6]

Improving tibial component alignment in total knee arthroplasty

CINOTTI, Gianluca;Giannicola G.
2014

Abstract

Abstract PURPOSE: Tibia torsion may influence the accuracy of extramedullary instrumentations in total knee arthroplasty (TKA). This study assessed whether the effect of tibial torsion may be overcome using a surgical technique in which the extramedullary rod is aligned to reference points at the proximal tibia only. METHODS: A consecutive series of 94 knees that underwent TKA were analyzed. In the first 47 knees (group 1), a standard procedure for tibial component alignment was performed while in the second group of 47 knees, a modified surgical technique was used including the alignment of the extramedullary rod to the reference points at the proximal tibia only (group 2). Lower limb, femoral, and tibial component alignment were measured on postoperative long-leg radiographs. RESULTS: Femorotibial mechanical axes angles were similar in the two groups. Femoral component alignment also did not differ between the groups. A neutral alignment of the tibial component was achieved in 17
2014
Purpose Tibia torsion may influence the accuracy of extramedullary instrumentations in total knee arthroplasty (TKA). This study assessed whether the effect of tibial torsion may be overcome using a surgical technique in which the extramedullary rod is aligned to reference points at the proximal tibia only. Methods A consecutive series of 94 knees that underwent TKA were analyzed. In the first 47 knees (group 1), a standard procedure for tibial component alignment was performed while in the second group of 47 knees, a modified surgical technique was used including the alignment of the extramedullary rod to the reference points at the proximal tibia only (group 2). Lower limb, femoral, and tibial component alignment were measured on postoperative long-leg radiographs. Results Femorotibial mechanical axes angles were similar in the two groups. Femoral component alignment also did not differ between the groups. A neutral alignment of the tibial component was achieved in 17 and 34 % of the knees in group 1 and group 2, respectively (p = 0.04). A malalignment of the tibial component >3° was found in 34 % of knees in group 1 compared with 4 % of those in group 2 (p = 0.0001). Conclusions Coronal alignment of the tibial component may improve by setting the extramedullary rod in line with anatomical references in the proximal tibia only. This technique appears to bypass the influence of tibial torsion on the alignment of the extramedullary guide at the distal tibia. The clinical relevance of the study is that using this technique, the rate of malalignment of the tibial component may be reduced compared to a standard technique in which a fixed reference is used at the ankle joint
Total knee arthroplasty Tibial cut Tibial component alignment Total knee alignment Extramedullary instrumentations
01 Pubblicazione su rivista::01a Articolo in rivista
Improving tibial component alignment in total knee arthroplasty / Cinotti, Gianluca; Sessa, P; D'Arino, A; Ripani, Fr; Giannicola, G.. - In: KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY. - ISSN 0942-2056. - STAMPA. - (2014), p. .... [10.1007/s00167-014-3236-6]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/733274
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact