In this paper, we present the first integration of an amorphous silicon balanced photosensor with a microfluidic network to perform on-chip detection for biomedical applications, where rejection of large background light intensity is needed. This solution allows to achieve high resolution readout without the need of high dynamic range electronics. The balanced photodiode is constituted by two-series-connected a-Si:H/a-SiC:H n-i-p stacked junctions, deposited on a glass substrate. The structure is a three terminal device where two electrodes bias the two diodes in reverse conditions while the third electrode (i.e., the connection point of the two diodes) provides the output signal given by the differential current. The microfluidic network is composed of two channels made in PolyDimetilSiloxane (PDMS) positioned over the glass substrate on the photodiode-side aligning each channel with a diode. This configuration guarantees an optimal optical coupling between luminescence events occurring in the channels and the photosensors. The experiments have been carried out measuring the differential current in identical and different conditions for the two channels. We have found that: the measurement dynamic range can be increased by at least an order of magnitude with respect to conventional photodiodes; the balanced photodiode is able to detect the presence or absence of water in the channel; the presence of fluorescent molecules in the channel can be successful detected by our device without any need of optical filter for the excitation light. These preliminary results demonstrate the successful integration of a microfluidic network with a-Si:H photosensor for on-chip detection in biomedical applications.

Amorphous silicon balanced photodiode for microuidic applications / Caputo, Domenico; DE CESARE, Giampiero; Nascetti, Augusto; Scipinotti, Riccardo. - STAMPA. - 8774:(2013), p. Article number 87740V. (Intervento presentato al convegno Conference on Optical Sensors tenutosi a Prague, CZECH REPUBLIC nel APR 15-17, 2013) [10.1117/12.2017420].

Amorphous silicon balanced photodiode for microuidic applications

CAPUTO, Domenico;DE CESARE, Giampiero;NASCETTI, Augusto;SCIPINOTTI, RICCARDO
2013

Abstract

In this paper, we present the first integration of an amorphous silicon balanced photosensor with a microfluidic network to perform on-chip detection for biomedical applications, where rejection of large background light intensity is needed. This solution allows to achieve high resolution readout without the need of high dynamic range electronics. The balanced photodiode is constituted by two-series-connected a-Si:H/a-SiC:H n-i-p stacked junctions, deposited on a glass substrate. The structure is a three terminal device where two electrodes bias the two diodes in reverse conditions while the third electrode (i.e., the connection point of the two diodes) provides the output signal given by the differential current. The microfluidic network is composed of two channels made in PolyDimetilSiloxane (PDMS) positioned over the glass substrate on the photodiode-side aligning each channel with a diode. This configuration guarantees an optimal optical coupling between luminescence events occurring in the channels and the photosensors. The experiments have been carried out measuring the differential current in identical and different conditions for the two channels. We have found that: the measurement dynamic range can be increased by at least an order of magnitude with respect to conventional photodiodes; the balanced photodiode is able to detect the presence or absence of water in the channel; the presence of fluorescent molecules in the channel can be successful detected by our device without any need of optical filter for the excitation light. These preliminary results demonstrate the successful integration of a microfluidic network with a-Si:H photosensor for on-chip detection in biomedical applications.
2013
Conference on Optical Sensors
balanced photodiode; hydrogenated amorphous silicon; lab-on-chip
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Amorphous silicon balanced photodiode for microuidic applications / Caputo, Domenico; DE CESARE, Giampiero; Nascetti, Augusto; Scipinotti, Riccardo. - STAMPA. - 8774:(2013), p. Article number 87740V. (Intervento presentato al convegno Conference on Optical Sensors tenutosi a Prague, CZECH REPUBLIC nel APR 15-17, 2013) [10.1117/12.2017420].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/695874
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact