The bimodal diagnostic systems like ultrasound/scintigraphic ones have the benefit of providing both morphological and physiological information. In the case in which it intends to develop a compact bimodal probe it is important that, as the readout electronics are doubled, the acquisition system is the most compact possible. In this paper we present the characterization and preliminary measurements on a multi-channel readout ASIC for PSPMTs. The chip is equipped with 32 readout channels, as different works show that single channel readout allows to exploit the performances of a gamma detector, especially for linearity. Each single channel readout is composed by a variable capacitor CSA, a sample and a variable gain amplifier (VGA). The possibility to change the gain of the amplifier allows to compensate for the differences in gain of the anodes of the PSPMT, while the possibility of changing the integrator capacitor allows to adapt the input dynamic of the chip depending on the PMT used (BA or SBA photocatode) and on the scintillation crystal coupled to the PMT itself. The preliminary measurements show that a 200 kHz maximum sampling rate is achievable, with 1V input dynamic and an overall linearity of the whole channel with respect to the input charge impulse of than 2%. To validate the performances of the ASIC different operative measurement was made in two configurations: with a single chip and two R11265-M16 PMTs, and, parallelizing two chips with a single PMT H8500. The tubes were coupled with scintillation crystals with different response speeds, from CsI to LaBr3. © 2013 IEEE.

Dedicated readout ASIC for dual modality probe / M., Galasso; V. o., Cencelli; Fabbri, Andrea; Bennati, Paolo; Cinti, Maria Nerina; Pani, Roberto; F. d., Notaristefani. - ELETTRONICO. - (2013), pp. Article number 6829779-1-Article number 6829779-6. (Intervento presentato al convegno 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 tenutosi a Seoul nel 27 October 2013 through 2 November 2013) [10.1109/nssmic.2013.6829779].

Dedicated readout ASIC for dual modality probe

FABBRI, ANDREA;BENNATI, Paolo;CINTI, Maria Nerina;PANI, Roberto;
2013

Abstract

The bimodal diagnostic systems like ultrasound/scintigraphic ones have the benefit of providing both morphological and physiological information. In the case in which it intends to develop a compact bimodal probe it is important that, as the readout electronics are doubled, the acquisition system is the most compact possible. In this paper we present the characterization and preliminary measurements on a multi-channel readout ASIC for PSPMTs. The chip is equipped with 32 readout channels, as different works show that single channel readout allows to exploit the performances of a gamma detector, especially for linearity. Each single channel readout is composed by a variable capacitor CSA, a sample and a variable gain amplifier (VGA). The possibility to change the gain of the amplifier allows to compensate for the differences in gain of the anodes of the PSPMT, while the possibility of changing the integrator capacitor allows to adapt the input dynamic of the chip depending on the PMT used (BA or SBA photocatode) and on the scintillation crystal coupled to the PMT itself. The preliminary measurements show that a 200 kHz maximum sampling rate is achievable, with 1V input dynamic and an overall linearity of the whole channel with respect to the input charge impulse of than 2%. To validate the performances of the ASIC different operative measurement was made in two configurations: with a single chip and two R11265-M16 PMTs, and, parallelizing two chips with a single PMT H8500. The tubes were coupled with scintillation crystals with different response speeds, from CsI to LaBr3. © 2013 IEEE.
2013
2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
capacitors; scintillation crystals; acquisition systems; voltage regulators; readout systems; physiological informations; probes; readout electronics; scintillation; nuclear physics; medical imaging; integrator capacitors; variable gain amplifiers; dual-modality probes; diagnostic systems
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Dedicated readout ASIC for dual modality probe / M., Galasso; V. o., Cencelli; Fabbri, Andrea; Bennati, Paolo; Cinti, Maria Nerina; Pani, Roberto; F. d., Notaristefani. - ELETTRONICO. - (2013), pp. Article number 6829779-1-Article number 6829779-6. (Intervento presentato al convegno 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 tenutosi a Seoul nel 27 October 2013 through 2 November 2013) [10.1109/nssmic.2013.6829779].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/691658
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact