The study presents the results of a campaign of measurements on the daily radon concentration using a Genitron Alpha Guard spectrometer. All the measurements have been intended to highlight the radon concentration variability during the 24 hours of the day and trying to find correlations with other ambient parameters such as temperature and pressure or local conditions such as the presence or not of a forced ventilation system. The main part of the measurements have been carried in the area of the Nuclear Measurement Laboratory of the Department of Basic and Applied Sciences for Engineering of “Sapienza” – University of Rome. Results show a rapid rise of radon concentration in the night, when the artificial ventilation system was off and with door and windows closed. In the morning, after the opening of door and windows, the concentration falls down abruptly. With artificial ventilation system in function concentration never reaches significant values. - Lo studio presenta i risultati sperimentali di una campagna di misura della concentrazione giornaliera di radon condotta utilizzando uno spettrometro Genitron AlphaGuard. Le misure hanno avuto lo scopo di evidenziare la variabilità della concentrazione di radon nell’arco delle 24 ore, allo scopo di cercare una correlazione con parametri ambientali, quali temperatura e pressione, o con condizioni locali, quali la presenza o meno di un sistema di ventilazione forzata. La maggior parte delle misure sono state condotte nell’area del Laboratorio di Misure Nucleari del Dipartimento di Scienze di Base e Applicate per l’Ingegneria di “Sapienza” – Università di Roma. I risultati ottenuti senza ventilazione forzata e con porte e finestre chiuse mostrano una rapida crescita della concentrazione di radon durante la notte. Al mattino, dopo l’apertura di porte e finestre, la concentrazione diminuisce bruscamente. Con il sistema di ventilazione forzata in funzione la concentrazione di radon non ha raggiunto mai valori significativi.

Experimental study on the influence of natural and artificial ventilation on indoor radon concentration [Studio sperimentale sull'influenza della ventilazione naturale e artificiale sulla concentrazione di radon indoor] / Remetti, Romolo; Gigante, Giovanni Ettore. - In: GIORNALE ITALIANO DI MEDICINA DEL LAVORO ED ERGONOMIA. - ISSN 1592-7830. - STAMPA. - 32:4 SUPPL. 1(2010), pp. 245-247.

Experimental study on the influence of natural and artificial ventilation on indoor radon concentration [Studio sperimentale sull'influenza della ventilazione naturale e artificiale sulla concentrazione di radon indoor]

REMETTI, Romolo;GIGANTE, Giovanni Ettore
2010

Abstract

The study presents the results of a campaign of measurements on the daily radon concentration using a Genitron Alpha Guard spectrometer. All the measurements have been intended to highlight the radon concentration variability during the 24 hours of the day and trying to find correlations with other ambient parameters such as temperature and pressure or local conditions such as the presence or not of a forced ventilation system. The main part of the measurements have been carried in the area of the Nuclear Measurement Laboratory of the Department of Basic and Applied Sciences for Engineering of “Sapienza” – University of Rome. Results show a rapid rise of radon concentration in the night, when the artificial ventilation system was off and with door and windows closed. In the morning, after the opening of door and windows, the concentration falls down abruptly. With artificial ventilation system in function concentration never reaches significant values. - Lo studio presenta i risultati sperimentali di una campagna di misura della concentrazione giornaliera di radon condotta utilizzando uno spettrometro Genitron AlphaGuard. Le misure hanno avuto lo scopo di evidenziare la variabilità della concentrazione di radon nell’arco delle 24 ore, allo scopo di cercare una correlazione con parametri ambientali, quali temperatura e pressione, o con condizioni locali, quali la presenza o meno di un sistema di ventilazione forzata. La maggior parte delle misure sono state condotte nell’area del Laboratorio di Misure Nucleari del Dipartimento di Scienze di Base e Applicate per l’Ingegneria di “Sapienza” – Università di Roma. I risultati ottenuti senza ventilazione forzata e con porte e finestre chiuse mostrano una rapida crescita della concentrazione di radon durante la notte. Al mattino, dopo l’apertura di porte e finestre, la concentrazione diminuisce bruscamente. Con il sistema di ventilazione forzata in funzione la concentrazione di radon non ha raggiunto mai valori significativi.
2010
ventilation; radon; indoor pollution
01 Pubblicazione su rivista::01a Articolo in rivista
Experimental study on the influence of natural and artificial ventilation on indoor radon concentration [Studio sperimentale sull'influenza della ventilazione naturale e artificiale sulla concentrazione di radon indoor] / Remetti, Romolo; Gigante, Giovanni Ettore. - In: GIORNALE ITALIANO DI MEDICINA DEL LAVORO ED ERGONOMIA. - ISSN 1592-7830. - STAMPA. - 32:4 SUPPL. 1(2010), pp. 245-247.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/68846
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact