Here the feasibility of layers based on the conducting polymer polyaniline (PANI) as component of glucose biosensors using glucose oxidase (GOx) as enzyme and [Os(bpy)2(4-aminomethylpyridine)Cl]PF6 (OsCmplx) as electrochemical mediator, is evaluated. Particularly, PANI was employed to obtain a nanostructured macroporous material (m-PANI) around polystyrene nanoparticles taken as template and the mediator was co-immobilized during the polymerizing procedure. The GOx biosensor based on OsCmplx modified m-PANI provides a linear response to glucose concentration in the range 5 up to 65mM with a sensitivity of 3.54μA/mM/cm2 (on a projected geometric area=0.07cm2), an LOD of 0.8mM and a good precision (%RSD≤7, n=5); the biosensor is stable showing a decrease of 10% to the value of the sensitivity after 15 days of use and of about 50% after 40 days.

Composite Material Based on Macroporous Polyaniline and Osmium Redox Complex for Biosensor Development / Antiochia, Riccarda; Mazzei, Franco; L., Gorton; D., Leech; Favero, Gabriele. - In: ELECTROANALYSIS. - ISSN 1040-0397. - STAMPA. - 26:(2014), pp. 1623-1630. [10.1002/elan.201400021]

Composite Material Based on Macroporous Polyaniline and Osmium Redox Complex for Biosensor Development

ANTIOCHIA, RICCARDA;MAZZEI, Franco;FAVERO, Gabriele
2014

Abstract

Here the feasibility of layers based on the conducting polymer polyaniline (PANI) as component of glucose biosensors using glucose oxidase (GOx) as enzyme and [Os(bpy)2(4-aminomethylpyridine)Cl]PF6 (OsCmplx) as electrochemical mediator, is evaluated. Particularly, PANI was employed to obtain a nanostructured macroporous material (m-PANI) around polystyrene nanoparticles taken as template and the mediator was co-immobilized during the polymerizing procedure. The GOx biosensor based on OsCmplx modified m-PANI provides a linear response to glucose concentration in the range 5 up to 65mM with a sensitivity of 3.54μA/mM/cm2 (on a projected geometric area=0.07cm2), an LOD of 0.8mM and a good precision (%RSD≤7, n=5); the biosensor is stable showing a decrease of 10% to the value of the sensitivity after 15 days of use and of about 50% after 40 days.
2014
01 Pubblicazione su rivista::01a Articolo in rivista
Composite Material Based on Macroporous Polyaniline and Osmium Redox Complex for Biosensor Development / Antiochia, Riccarda; Mazzei, Franco; L., Gorton; D., Leech; Favero, Gabriele. - In: ELECTROANALYSIS. - ISSN 1040-0397. - STAMPA. - 26:(2014), pp. 1623-1630. [10.1002/elan.201400021]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/675737
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact